Diagnostic yield of conventional and digital cephalometric images: a human cadaver study

被引:17
作者
Gijbels, F [1 ]
Serhal, CB [1 ]
Willems, G [1 ]
Bosmans, H [1 ]
Sanderink, G [1 ]
Persoons, M [1 ]
Jacobs, R [1 ]
机构
[1] Katholieke Univ Leuven, Sch Dent Oral Pathol & Maxillofacial Surg, B-3000 Louvain, Belgium
关键词
digital radiography; dental; radiography; radiation dosage; cephalometry;
D O I
10.1038/sj.dmfr.4600585
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the clinical efficacy of digital and conventional cephalometric imaging. Methods: Conventional and photostimulable phosphor cephalometric radiographs were obtained from three human cadavers at nine different exposure settings. Subjective image quality was assessed by six observers who evaluated six cephalometric landmarks. Organ doses were measured with TLDs and effective doses calculated. Results: Compared with conventional cephalometric images, digital images had a consistently better subjective image quality for all exposure settings which was significant (P<0.05) for all but two. Organ doses were comparable. Higher kV and lower mAs settings yielded the lowest effective dose, which was highly dependent on the position of the thyroid gland in the beam. Conclusion: Relatively small variations in exposure settings do not influence subjective diagnostic image quality of digital cephalometric radiographs. Higher kV and lower mAs settings have the lowest effective dose and should therefore be preferred.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 21 条
[11]   Detection of radiographic findings in lung fibrosis using storage phosphor plates [J].
Muller, RD ;
Herting, D ;
Hirche, H ;
John, V ;
Buddenbrock, B ;
Gocke, P ;
Wiebringhaus, R ;
Konietzko, N ;
Langer, R .
EUROPEAN RADIOLOGY, 1997, 7 (04) :576-582
[12]   Analysis of low-dose digital lateral cephalometric radiographs [J].
Naslund, EB ;
Kruger, M ;
Petersson, A ;
Hansen, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (03) :136-139
[13]   Comparative reject analysis in conventional film-screen and digital storage phosphor radiography [J].
Peer, S ;
Peer, R ;
Walcher, M ;
Pohl, M ;
Jaschke, W .
EUROPEAN RADIOLOGY, 1999, 9 (08) :1693-1696
[14]  
Preston-Martin S, 1985, Natl Cancer Inst Monogr, V69, P175
[15]   BRAIN AND SALIVARY-GLAND TUMORS RELATED TO PRIOR DENTAL RADIOGRAPHY - IMPLICATIONS FOR CURRENT PRACTICE [J].
PRESTONMARTIN, S ;
WHITE, SC .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1990, 120 (02) :151-158
[16]   PRIOR EXPOSURE TO MEDICAL AND DENTAL X-RAYS RELATED TO TUMORS OF THE PAROTID-GLAND [J].
PRESTONMARTIN, S ;
THOMAS, DC ;
WHITE, SC ;
COHEN, D .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1988, 80 (12) :943-949
[17]  
Pujol A Jr, 1982, Dentomaxillofac Radiol, V11, P25
[18]   Computing patient doses of x-ray examinations using a patient size- and sex-adjustable phantom [J].
Rannikko, S ;
Ermakov, I ;
Lampinen, JS ;
Toivonen, M ;
Karila, KTK ;
Chervjakov, A .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (835) :708-718
[19]  
*REP JOINT WORK PA, 1985, DR DENT J, V158, P415
[20]   EXPOSURE REDUCTION IN CEPHALOGRAPHY WITH A DIGITAL PHOTOSTIMULABLE PHOSPHOR IMAGING-SYSTEM [J].
SEKI, K ;
OKANO, T .
DENTOMAXILLOFACIAL RADIOLOGY, 1993, 22 (03) :127-130