On-line preconcentration and chiral separation of propiconazole by cyclodextrin-modified micellar electrokinetic chromatography

被引:43
作者
Ibrahim, Wan Aini Wan [1 ]
Hermawan, Dadan [1 ]
Sanagi, Mom Marsin [1 ]
机构
[1] Univ Teknol Malaysia, Fac Sci, Dept Chem, Separat Sci Res Grp, Skudai 81310, Johor, Malaysia
关键词
propiconazole; chiral triazole fungicides; enantiomer separation; capillary electrophoresis; CD-MEKC; on-line preconcentration; stacking; sweeping;
D O I
10.1016/j.chroma.2007.09.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the chiral separation of propiconazole using cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC with hydroxypropyl-gamma-cyclodextrin (HP-gamma-CD) as chiral selector is reported. The use of a mixture of 30 mM HP-gamma-CD, 50 mM SDS, methanol-acetonitrile 10%:5% (v/v) in 25 mM phosphate buffer solution was able to separate two enantiomeric pairs of propiconazole. Stacking-and sweeping-CD-MEKC under neutral pH (pH 7) and under acidic condition (pH 3.0) were used as two on-line preconcentration methods to increase detection sensitivity of propiconazole. Good repeatabilities in the migration time, peak area and peak height were obtained in terms of relative standard deviation (RSD). A sensitivity enhancement factor of 100-fold was achieved using sweeping-CD-MEKC at acidic pH. This is the first report on the separation of two pairs of propiconazole enantiomers and all the enantiomers of fenbuconazole and tebuconazole using sweeping-CD-MEKC. The limit of detection (S/N = 3) for the three triazole fungicides ranged from 0.09 to 0.1 mu g/mL, which is well below the maximum residue limits (MRL) set by Codex Alimentarius Commission (CAC. Combination of solid-phase extraction (SPE) pretreatment and sweeping-CD-MEKC procedure was applied to the determination of selected triazole fungicides in grapes samples spiked at concentration 10-40 times lower than the MRL established by the CAC. The average recoveries of the selected fungicides in spiked grapes samples were good, ranging from 73% to 109% with RSD of 9-12% (n = 3). (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 28 条
[1]   Optimization and validation of a gas chromatographic method for analysis of (RS,SR)-diastereoisomeric impurity in formoterol fumarate [J].
Akapo, SO ;
Wegner, M ;
Mamangun, A ;
McCrea, C ;
Asif, M ;
Dussex, JC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :211-216
[2]   Thin-layer chromatographic separation of enantiomeric dansylamino acids using a macrocyclic antibiotic as a chiral selector [J].
Bhushan, R ;
Parshad, V .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :235-238
[3]  
BIOSCA YM, 2000, ELECTROPHORESIS, V21, P3240
[4]   Separation selectivity in chiral capillary electrophoresis with charged selectors [J].
Chankvetadze, B .
JOURNAL OF CHROMATOGRAPHY A, 1997, 792 (1-2) :269-295
[5]  
Edwards SH, 2002, ELECTROPHORESIS, V23, P1320, DOI 10.1002/1522-2683(200205)23:9<1320::AID-ELPS1320>3.0.CO
[6]  
2-9
[7]   Enantiomer separation by capillary electrochromatography using fritless packed columns [J].
Fujimoto, C .
ANALYTICAL SCIENCES, 2002, 18 (01) :19-25
[8]   LIQUID-CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF DINICONAZOLE USING A BETA-CYCLODEXTRIN-BONDED COLUMN [J].
FURUTA, R ;
NAKAZAWA, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 625 (02) :231-235
[9]  
GARCIA AJ, 2005, J CHROMATOGR A, V1073, P229
[10]   Chiral separations in microemulsion electrokinetic chromatography - Use of micelle polymers and microemulsion polymers [J].
Iqbal, R ;
Rizvi, SAA ;
Akbay, C ;
Shamsi, SA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1043 (02) :291-302