Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species

被引:898
作者
Chen, Xiaoqiang [2 ,3 ,4 ]
Tian, Xizhe [1 ]
Shin, Injae [1 ]
Yoon, Juyoung [2 ,3 ]
机构
[1] Yonsei Univ, Dept Chem, Ctr Biofunct Mol, Seoul 120749, South Korea
[2] Ewha Womans Univ, Dept Chem & Nano Sci, Seoul 120750, South Korea
[3] Ewha Womans Univ, Dept Bioinspired Sci WCU, Seoul 120750, South Korea
[4] Nanjing Univ Technol, State Key Lab Mat Oriented Chem Engn, Coll Chem & Chem Engn, Nanjing 210009, Peoples R China
基金
新加坡国家研究基金会;
关键词
NITRIC-OXIDE DETECTION; FLOW-INJECTION SPECTROFLUOROMETRY; SUPEROXIDE ANION-RADICALS; IMAGING HYDROGEN-PEROXIDE; LIVING CELLS; SINGLET-OXYGEN; HYDROXYL RADICALS; IN-VIVO; RATIONAL DESIGN; SELECTIVE DETECTION;
D O I
10.1039/c1cs15037e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Oxidative and nitrosative stress induced by ROS/RNS play crucial roles in a wide range of physiological processes and are also implicated in various diseases, including cancer and neurodegenerative disorders. Sensitive and selective methods for the detection of ROS/RNS based on fluorescent and luminescent probes are of great use in monitoring the in vivo production of these species and elucidating their biological functions. This critical review highlights recent advances that have been made in the development of fluorescent and luminescent probes employed to monitor various ROS/RNS (132 references).
引用
收藏
页码:4783 / 4804
页数:22
相关论文
共 137 条
[91]   Simple triphenylamine-based luminophore as a hypochlorite chemosensor [J].
Shi, Jie ;
Li, Qianqian ;
Zhang, Xing ;
Peng, Ming ;
Qin, Jingui ;
Li, Zhen .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :583-587
[92]   Gold nanodot-based luminescent sensor for the detection of hydrogen peroxide and glucose [J].
Shiang, Yen-Chun ;
Huang, Chih-Ching ;
Chang, Huan-Tsung .
CHEMICAL COMMUNICATIONS, 2009, (23) :3437-3439
[93]   Oxygen, oxysterols, ouabain, and ozone: A cautionary tale [J].
Smith, LL .
FREE RADICAL BIOLOGY AND MEDICINE, 2004, 37 (03) :318-324
[94]   Conjugated polymer-based fluorescence turn-on sensor for nitric oxide [J].
Smith, RC ;
Tennyson, AG ;
Lim, MH ;
Lippard, SJ .
ORGANIC LETTERS, 2005, 7 (16) :3573-3575
[95]   Design and development of a fluorescent probe for monitoring hydrogen peroxide using photoinduced electron transfer [J].
Soh, N ;
Sakawaki, O ;
Makihara, K ;
Odo, Y ;
Fukaminato, T ;
Kawai, T ;
Irie, M ;
Imato, T .
BIOORGANIC & MEDICINAL CHEMISTRY, 2005, 13 (04) :1131-1139
[96]   A ratiometric fluorescent probe for imaging hydroxyl radicals in living cells [J].
Soh, N ;
Makihara, K ;
Sakoda, E ;
Imato, T .
CHEMICAL COMMUNICATIONS, 2004, (05) :496-497
[97]   Ratiometric direct detection of nitric oxide based on a novel signal-switching mechanism [J].
Soh, N ;
Imato, T ;
Kawamura, K ;
Maeda, M ;
Katayama, Y .
CHEMICAL COMMUNICATIONS, 2002, (22) :2650-2651
[98]   Phospholipid-linked coumarin: A fluorescent probe for sensing hydroxyl radicals in lipid membranes [J].
Soh, Nobuaki ;
Makihara, Koji ;
Ariyoshi, Tomoyuki ;
Seto, Daisuke ;
Maki, Tomoharu ;
Nakajima, Hizuru ;
Nakano, Koji ;
Imato, Toshihiko .
ANALYTICAL SCIENCES, 2008, 24 (02) :293-296
[99]   A new europium chelate-based phosphorescence probe specific for singlet oxygen [J].
Song, B ;
Wang, GL ;
Yuan, JL .
CHEMICAL COMMUNICATIONS, 2005, (28) :3553-3555
[100]   A europium(III) complex as an efficient singlet oxygen luminescence probe [J].
Song, Bo ;
Wang, Guilan ;
Tan, Mingqian ;
Yuan, Jingli .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (41) :13442-13450