Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality

被引:31
作者
Blankstein, Ron [1 ,2 ,3 ,4 ]
Bolen, Michael A. [5 ]
Pale, Rodrigo [2 ,3 ,4 ]
Murphy, Meagan K. [2 ,3 ,4 ]
Shah, Amar B. [2 ,3 ,4 ]
Bezerra, Hiram G. [2 ,3 ,4 ]
Sarwar, Ammar [2 ,3 ,4 ]
Rogers, Ian S. [2 ,3 ,4 ]
Hoffmann, Udo [2 ,3 ,4 ]
Abbara, Suhny [2 ,3 ,4 ]
Cury, Ricardo C. [2 ,3 ,4 ,6 ]
Brady, Thomas J. [2 ,3 ,4 ]
机构
[1] Brigham & Womens Hosp, Noninvas Cardiovasc Imaging Program, Dept Med & Radiol, Cardiovasc Div, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Cardiac MR PET CT Program, Dept Radiol, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Div Cardiol, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
[5] Cleveland Clin, Cardiovasc Sect, Imaging Inst, Cleveland, OH 44195 USA
[6] Baptist Cardiac & Vasc Inst, Miami, FL 33176 USA
关键词
Cardiac CT; Radiation dose; Tube voltage; CT ANGIOGRAPHY; EXPOSURE;
D O I
10.1007/s10554-010-9683-3
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
To evaluate the effective radiation dose and image quality resulting from use of 100 vs. 120 kV among patients referred for cardiac dual source CT exam (DSCT). Prospective data was collected on 294 consecutive patients referred for DSCT. For each scan, a physician specializing in cardiac CT chose all parameters including tube current and voltage, axial versus helical acquisition, and use of tube current modulation. Lower tube voltage was selected for thinner patients or when lower radiation was desired for younger patients, particularly females. For each study, image quality (IQ) was rated on a subjective IQ score and contrast (CNR) and signal-to-noise (SNR) ratios were calculated. Tube voltage of 100 kV was used for 77 (26%) exams while 120 kV was used for 217 (74%) exams. Use of 100 kV was more common in thinner patients (weight 166lbs vs. 199lbs, P < .001). The effective radiation dose for the 100 and 120 kV scans was 8.5 and 15.4 mSv respectively. Among scans utilizing 100 and 120 kV, there was no difference in exam indication, use of beta blockers, heart rate, scan length and use of radiation saving techniques such as prospective ECG triggering and tube current modulation. The IQ score was significantly higher for 100 kV scans. While 100 kV scans were found to have higher image noise then those utilizing 120 kV, the contrast-to-noise and signal-to-noise were significantly higher (SNR: 9.4 vs. 8.3, P = .02; CNR: 6.9 vs. 6.0, P = .02). In selected non-obese patients, use of low kV results in a substantial reduction of radiation dose and may result in improved image quality. These results suggest that low kV should be used more frequently in non-obese patients.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 10 条
[1]
Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Plass, Andre ;
Genoni, Michele ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :385-391
[2]
BLUEMKE DA, 2008, CIRCULATION
[3]
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[4]
Radiation Protection of Patients Undergoing Cardiac Computed Tomographic Angiography [J].
Einstein, Andrew J. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :545-547
[5]
Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study [J].
Feuchtner, Gudrun M. ;
Jodocy, Daniel ;
Klauser, Andrea ;
Haberfellner, Bernhard ;
Aglan, Iman ;
Spoeck, Alexander ;
Hiehs, Stefan ;
Soegner, Peter ;
Jaschke, Werner .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (01) :E51-E56
[6]
Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[7]
Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[8]
Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[9]
Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose [J].
Leschka, Sebastian ;
Stolzmann, Paul ;
Schmid, Florian T. ;
Scheffel, Hans ;
Stinn, Bjoern ;
Marincek, Borut ;
Alkadhi, Hatem ;
Wildermuth, Simon .
EUROPEAN RADIOLOGY, 2008, 18 (09) :1809-1817
[10]
Strategies for reduction of radiation dose in cardiac multislice CT [J].
Paul, Jean-Francois ;
Abada, Hicham T. .
EUROPEAN RADIOLOGY, 2007, 17 (08) :2028-2037