Towards the development of an integrated capillary electrophoresis optical biosensor

被引:11
作者
Bossi, A
Castelletti, L
Piletsky, SA
Turner, APF
Righetti, PG
机构
[1] Univ Verona, Dept Sci & Technol, I-37134 Verona, Italy
[2] Cranfield Univ, Inst Biosci & Technol, Silsoe, Beds, England
关键词
biosensor; capillary electrophoresis; chemical sensor; glucose oxidase; redox analytes;
D O I
10.1002/elps.200305588
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extending the previous preliminary study on the construction of a capillary electrophoresis (CE)/sensor for the detection of reducing analytes, we focus the interest on the simultaneous detection of redox active species, which are important indicators of the oxidative damage in tissues, of food preservation, and of pollution. The CE/sensor was built by modifying the detector-portion of the capillary with the redox-sensitive polymer polyaniline (PANI). The analyte is detected by monitoring the changes in optical absorption of the PANI film. The CE/sensor was tested, with good results, with ascorbic acid, glutathione (GSH), as well as with compounds with very close similarity (ascorbic and isoascorbic acid). The kinetics of oxidation and reduction of PANI were evaluated. Further a PANI/CE-biological sensor was developed by coupling an enzyme, glucose oxidase (GOD), to the PANI-modified portion of the capillary. The stability of the immobilized GOD and the sensitivity of the CE/biosensor were studied, by using glucose as test analyte in concentrations within the physiological range. The results indicate that the CE/biosensor had good stability (more than 75% of original activity retained after 30 operational days), manufacturing reproducibility and a sensing range convenient for monitoring physiological glucose (1-24 mm).
引用
收藏
页码:3356 / 3363
页数:8
相关论文
共 31 条
[1]   The free radical theory of aging matures [J].
Beckman, KB ;
Ames, BN .
PHYSIOLOGICAL REVIEWS, 1998, 78 (02) :547-581
[2]   Capillary electrophoresis coupled to biosensor detection [J].
Bossi, A ;
Piletsky, SA ;
Righetti, PG ;
Turner, APF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :143-153
[3]   An assay for ascorbic acid based on polyaniline-coated microplates [J].
Bossi, A ;
Piletsky, SA ;
Piletska, EV ;
Righetti, PG ;
Turner, APF .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4296-4300
[4]   Polypyrrole-hydrogel composites for the construction of clinically important biosensors [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :53-59
[5]  
Castelletti L, 2002, ELECTROPHORESIS, V23, P209, DOI 10.1002/1522-2683(200202)23:2&lt
[6]  
209::AID-ELPS209&gt
[7]  
3.0.CO
[8]  
2-D
[9]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[10]   The effect of glutaraldehyde on the electrochemical behavior of polyaniline [J].
de Melo, JV ;
Bello, ME ;
de Azevêdo, WM ;
de Souza, JM ;
Diniz, FB .