Towards the development of an integrated capillary electrophoresis optical biosensor

被引:11
作者
Bossi, A
Castelletti, L
Piletsky, SA
Turner, APF
Righetti, PG
机构
[1] Univ Verona, Dept Sci & Technol, I-37134 Verona, Italy
[2] Cranfield Univ, Inst Biosci & Technol, Silsoe, Beds, England
关键词
biosensor; capillary electrophoresis; chemical sensor; glucose oxidase; redox analytes;
D O I
10.1002/elps.200305588
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extending the previous preliminary study on the construction of a capillary electrophoresis (CE)/sensor for the detection of reducing analytes, we focus the interest on the simultaneous detection of redox active species, which are important indicators of the oxidative damage in tissues, of food preservation, and of pollution. The CE/sensor was built by modifying the detector-portion of the capillary with the redox-sensitive polymer polyaniline (PANI). The analyte is detected by monitoring the changes in optical absorption of the PANI film. The CE/sensor was tested, with good results, with ascorbic acid, glutathione (GSH), as well as with compounds with very close similarity (ascorbic and isoascorbic acid). The kinetics of oxidation and reduction of PANI were evaluated. Further a PANI/CE-biological sensor was developed by coupling an enzyme, glucose oxidase (GOD), to the PANI-modified portion of the capillary. The stability of the immobilized GOD and the sensitivity of the CE/biosensor were studied, by using glucose as test analyte in concentrations within the physiological range. The results indicate that the CE/biosensor had good stability (more than 75% of original activity retained after 30 operational days), manufacturing reproducibility and a sensing range convenient for monitoring physiological glucose (1-24 mm).
引用
收藏
页码:3356 / 3363
页数:8
相关论文
共 31 条
[11]   Modular separation-based fiber-optic sensors for remote in situ monitoring [J].
Dickens, J ;
Sepaniak, M .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (01) :11-16
[12]  
Foyer C.H., 1993, Antioxidants in higher plants, P31
[13]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359
[14]  
Haber C, 1996, J CAPILLARY ELECTROP, V3, P1
[15]   Monodehydroascorbate radical detected by electron paramagnetic resonance spectrometry is a sensitive probe of oxidative stress in intact leaves [J].
Heber, U ;
Miyake, C ;
Mano, J ;
Ohno, C ;
Asada, K .
PLANT AND CELL PHYSIOLOGY, 1996, 37 (08) :1066-1072
[16]   An enzyme-chemically modified carbon paste electrode as a glucose sensor based on glucose oxidase immobilized in a polyaniline film [J].
Hu, SS ;
Luo, J ;
Cui, D .
ANALYTICAL SCIENCES, 1999, 15 (06) :585-588
[17]   Polyaniline: A polymer with many interesting intrinsic redox states [J].
Kang, ET ;
Neoh, KG ;
Tan, KL .
PROGRESS IN POLYMER SCIENCE, 1998, 23 (02) :277-324
[18]   Skin antioxidants: their role in aging and in oxidative stress - New approaches for their evaluation [J].
Kohen, R .
BIOMEDICINE & PHARMACOTHERAPY, 1999, 53 (04) :181-192
[19]   ELECTRON-TRANSFER ON AN ELECTRODE OF GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE [J].
LU, SY ;
LI, CF ;
ZHANG, DD ;
ZHANG, Y ;
MO, ZH ;
CAI, Q ;
ZHU, AR .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 364 (1-2) :31-36
[20]   NMR spectroscopic study of the formation of borate esters ascorbic acid and isoascorbic acid [J].
Obi, N ;
Katayama, M ;
Sano, J ;
Kojima, Y ;
Shigemitsu, Y ;
Takada, B .
NEW JOURNAL OF CHEMISTRY, 1998, 22 (09) :933-934