Matrix effect studies in the inductively coupled plasma with monodisperse droplets. Part 1: The influence of matrix on the vertical analyte emission profile

被引:35
作者
Lazar, AC [1 ]
Farnsworth, PB [1 ]
机构
[1] Brigham Young Univ, Dept Biochem & Chem, Provo, UT 84602 USA
关键词
matrix effects; inductively coupled plasma atomic emission spectroscopy (ICP-AES); radiative heat transfer; droplet desolvation; monodisperse dried microparticulate injector (MDMI);
D O I
10.1366/0003702991946749
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The effects of different matrices on the analyte vertical emission profile in the inductively coupled plasma were evaluated with use of a monodisperse droplet sample introduction system in combination with a pneumatic nebulizer. The influence of matrix in the gas phase was separated from influences in the desolvation and volatilization steps. The results suggest that vertical shifts in the analyte emission profiles occur primarily during droplet desolvation and vaporization. The vertical shifts can be correlated to the size of the desolvated particles; larger particles produce emission profiles closer to the load coil, Possible effects of radiative heat transfer were also studied. Strongly absorbing species can increase the evaporation rate of the solvent and produce vertical shifts toward the load coil.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 26 条
[11]  
HORNER JA, IN PRESS SPECTROCHIM, V53
[12]   High speed photographic study of wet droplets and solid particles in the inductively coupled plasma [J].
Houk, RS ;
Winge, RK ;
Chen, XS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) :1139-1148
[13]   EFFECTS OF MATRIX ON SPATIAL PROFILES OF EMISSION FROM AN INDUCTIVELY COUPLED PLASMA [J].
KAWAGUCHI, H ;
ITO, T ;
OTA, K ;
MIZUIKE, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (04) :199-206
[14]   Investigation of the analytical performance of an MDMI-ICP-AES system [J].
Lazar, AC ;
Farnsworth, PB .
APPLIED SPECTROSCOPY, 1997, 51 (05) :617-624
[15]   IMPROVED PERFORMANCE USING INTERNAL STANDARDIZATION IN INDUCTIVELY-COUPLED PLASMA EMISSION-SPECTROSCOPY [J].
MYERS, SA ;
TRACY, DH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (09) :1227-1253
[16]   Signal enhancement effect of halogen matrix in electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Nonose, N ;
Matsuda, N ;
Fudagawa, N ;
Kubota, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (12) :1551-1565
[17]   Observation of atom and ion clouds produced from single droplets of sample in inductively coupled plasmas by optical emission and laser-induced fluorescence imaging [J].
Olesik, JW ;
Kinzer, JA ;
McGowan, GJ .
APPLIED SPECTROSCOPY, 1997, 51 (05) :607-616
[18]   CHARACTERIZATION OF AEROSOLS PRODUCED BY PNEUMATIC NEBULIZERS FOR INDUCTIVELY-COUPLED PLASMA SAMPLE INTRODUCTION - EFFECT OF LIQUID AND GAS POW RATES ON VOLUME BASED DROP SIZE DISTRIBUTIONS [J].
OLESIK, JW ;
BATES, LC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :285-303
[19]   Investigating the fate of individual sample droplets in inductively coupled plasmas [J].
Olesik, JW .
APPLIED SPECTROSCOPY, 1997, 51 (05) :A158-A175
[20]   EASILY AND NONEASILY IONIZABLE ELEMENT MATRIX EFFECTS IN INDUCTIVELY COUPLED PLASMA OPTICAL SPECTROMETRY [J].
OLESIK, JW ;
WILLIAMSEN, EJ .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1223-1232