Contrast-enhanced MR angiography at 1.5 T after implantation of platinum stents: In vitro and in vivo comparison with conventional stent designs

被引:19
作者
Hagspiel, KD
Leung, DA
Nandalur, KR
Angle, JF
Dulai, HS
Spinosa, DJ
Matsumoto, AH
Christopher, JM
Ahmed, H
Berr, SS
机构
[1] Univ Virginia Hlth Syst, Dept Radiol, Div Intervent Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
关键词
D O I
10.2214/ajr.184.1.01840288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate the in vitro and in vivo 3D contrast-enhanced MR angiography characteristics of a new platinum-based balloon-expandable stent system and compare this system with a variety of competing metallic stents. MATERIALS AND METHODS. All experiments were performed on 1.5-T scanners. In vitro experiments were performed using 10 stents implanted into a custom-built phantom. Different orientations of the stents along the magnetic field and multiple flip angles were examined. In addition, 19 patients underwent contrast-enhanced MR angiography after the implantation of 36 stents, including four patients with six platinum stents. Angiographic correlation was available for all 19 patients, and luminal patency and stent-induced artifacts were S assessed quantitatively. RESULTS. Of the tested balloon-expandable stents, only the platinum-based stents created artifact causing luminal narrowing of 30% or less. All other balloon-expandable stents induced larger artifacts that resulted in higher degrees of narrowing. Thus, if patent, the platinum-based stents allow significant in-stent stenosis to be ruled out reliably. Selected nitinol- or tantalum-based self-expandable stents also are suitable in this regard. CONCLUSION. Of the tested devices, platinum-based stents are the only type of currently available balloon-expandable stent that creates 30% or less artifact-induced apparent stenosis and thus are suitable for MR angiography.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 21 条
[1]   SUSCEPTIBILITY ARTIFACTS IN 2DFT SPIN-ECHO AND GRADIENT-ECHO IMAGING - THE CYLINDER MODEL REVISITED [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
FUDERER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :539-548
[2]   Improved lumen visualization in metallic vascular implants by reducing RF artifacts [J].
Bartels, LW ;
Bakker, CJG ;
Viergever, MA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :171-180
[3]   Thin-section multidetector CT angiography of renal artery stents [J].
Behar, JV ;
Nelson, RC ;
Zidar, JP ;
DeLong, DM ;
Smith, TP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1155-1159
[4]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[5]   In vivo evaluation of intravascular stents at three-dimensional MR angiography [J].
Cavagna, E ;
Berletti, R ;
Schiavon, F .
EUROPEAN RADIOLOGY, 2001, 11 (12) :2531-2535
[6]  
Engellau L, 2000, J MAGN RESON IMAGING, V12, P112, DOI 10.1002/1522-2586(200007)12:1<112::AID-JMRI13>3.0.CO
[7]  
2-G
[8]   Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography [J].
Hilfiker, PR ;
Quick, HH ;
Debatin, JF .
RADIOLOGY, 1999, 211 (03) :693-697
[9]   Three-dimensional contrast-enhanced MR angiography sf endovascular covered stents in patients with peripheral arterial occlusive disease [J].
Juergens, KU ;
Tombach, B ;
Reimer, P ;
Vestring, T ;
Heindel, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1299-1303
[10]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO