Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization

被引:25
作者
Braekken, SK
Endresen, K
Russell, D
Brucher, R
Kjekshus, J
机构
[1] Univ Oslo, Natl Hosp, Rikshosp, Dept Neurol, Oslo, Norway
[2] Univ Oslo, Natl Hosp, Rikshosp, Dept Internal Med, Oslo, Norway
关键词
D O I
10.1016/S0002-9149(98)00407-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cerebral embolization is a serious complication during diagnostic heart catheterization, To date there have been no studies to determine whether the technique and the catheter type influence the frequency of cerebral microembolic signals (MES's) during left ventricular catheterization, Twenty-two patients had a leading straight tip guidewire protruding 5 to 10 cm outside the coronary catheters when the latter was advanced over the aortic arch (group A), whereas in 21 patients the guidewire was withdrawn in the descending part of the aorta (group B), Transcranial Doppler of the left middle cerebral artery was performed to monitor the number of cerebral MES's. When a protruding guidewire was used to advance the coronary catheters over the aortic arch, MES's were detected in 86% of the patients compared with 29% when the catheters were advanced without a guidewire (relative risk = 4.6, p = 0.00001) The number of MES's per patient also was significantly higher when a guidewire was used (median 9 vs 0) (p = 0.000004). In group A, a higher number of MES's was detected when a right Judkins catheter was advanced over the aortic arch than when a left Judkins catheter was advanced (median 6.5 vs 1) (p = 0.0005) and in patients who previously had a myocardial infarction than in those who had not (median 1 1 vs 4) (p = 0.007). This study strongly suggests that the risk of embolization is greater when straight tip guidewires are used to advance catheters over the aortic arch during left ventricular heart catheterization, especially in patients with a history of myocardial infarction. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 18 条
[1]  
BRAEKKEN SK, 1998, J NEUROL NEUROSUR PS, V65, P1
[2]   TRANSESOPHAGEAL ECHOCARDIOGRAPHICALLY DETECTED ATHEROSCLEROTIC AORTIC PLAQUE IS A MARKER FOR CORONARY-ARTERY DISEASE [J].
FAZIO, GP ;
REDBERG, RF ;
WINSLOW, T ;
SCHILLER, NB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :144-150
[3]   SYSTEMIC GASEOUS MICROEMBOLI DURING LEFT ATRIAL CATHETERIZATION - A COMMON OCCURRENCE [J].
FEERICK, AE ;
CHURCH, JA ;
ZWISCHENBERGER, J ;
CONTI, V ;
JOHNSTON, WE .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) :395-398
[4]   Microemboli during carotid angiography - Association with stroke risk factors or subsequent magnetic resonance imaging changes? [J].
Gerraty, RP ;
Bowser, DN ;
Infeld, B ;
Mitchell, PJ ;
Davis, SM .
STROKE, 1996, 27 (09) :1543-1547
[5]   INVIVO THROMBUS FORMATION ON A GUIDEWIRE DURING INTRAVASCULAR ULTRASOUND IMAGING - EVIDENCE FOR INADEQUATE HEPARINIZATION [J].
GRAYBURN, PA ;
WILLARD, JE ;
BRICKNER, ME ;
EICHHORN, EJ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 23 (02) :141-143
[6]   SELECTIVE CORONARY ARTERIOGRAPHY .I. A PERCUTANEOUS TRANSFEMORAL TECHNIC [J].
JUDKINS, MP .
RADIOLOGY, 1967, 89 (05) :815-&
[7]   Risk of catheter-related emboli in patients with atherosclerotic debris in the thoracic aorta [J].
Karalis, DG ;
Quinn, V ;
Victor, MF ;
Ross, JJ ;
Polansky, M ;
Spratt, KA ;
Chandrasekaran, K .
AMERICAN HEART JOURNAL, 1996, 131 (06) :1149-1155
[8]  
Khan K A, 1995, J Stroke Cerebrovasc Dis, V5, P187, DOI 10.1016/S1052-3057(10)80188-0
[9]   Frequency and distribution at atherosclerotic plaques in the thoracic aorta as determined by transesophageal echocardiography in patients with coronary artery disease [J].
Khoury, Z ;
Gottlieb, S ;
Stern, S ;
Keren, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (01) :23-27
[10]   MICROSCOPIC AIR-EMBOLISM DURING CEREBRAL-ANGIOGRAPHY AND STRATEGIES FOR ITS AVOIDANCE [J].
MARKUS, H ;
LOH, A ;
ISRAEL, D ;
BUCKENHAM, T ;
CLIFTON, A ;
BROWN, MM .
LANCET, 1993, 341 (8848) :784-787