摘要
The performance of carbon nanotubes paste electrodes (CNTPE) prepared by dispersion of multi-wall carbon nanotubes (MWNT) within mineral oil is described. The resulting electrode shows an excellent electrocatalytic activity toward ascorbic acid, uric acid, dopamine, 3.4-dihydroxyphenylacetic acid (dopac) and hydrogen peroxide. These properties permit an important decrease in the overvoltage for the oxidation of ascorbic acid (230 mV), uric acid (160 mV) and hydrogen peroxide (300 mV) as well as a dramatic improvement in the reversibility of the redox behavior of dopamine and dopac, in comparison with the classical carbon (graphite) paste electrodes (CPE). The substantial decrease in the overvoltage of the hydrogen peroxide reduction (400 mV) associated with a successful incorporation of glucose oxidase (GOx) into the composite material, allow the development of a highly selective and sensitive glucose biosensor without using any metal, redox mediator or anti-interference membrane. No interference was observed at -0.100 V even for large excess of ascorbic acid, uric acid and acetaminophen. A linear response up to 30 mM (5.40 g l(-1)) glucose with a detection limit of 0.6 mM (0.11 g l(-1)) were obtained with the CNTPE modified with 10% w/w GOx. Such an excellent performance of CNTPE toward hydrogen peroxide, represents a very good alternative for developing other enzymatic biosensors. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:689 / 694
页数:6
相关论文
共 18 条
  • [11] Glassy carbon paste electrodes modified with polyphenol oxidase -: Analytical applications
    Rodríguez, MC
    Rivas, GA
    [J]. ANALYTICA CHIMICA ACTA, 2002, 459 (01) : 43 - 51
  • [12] Carbon nanotube/teflon composite electrochemical sensors and biosensors
    Wang, J
    Musameh, M
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2075 - 2079
  • [13] Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors
    Wang, J
    Musameh, M
    Lin, YH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (09) : 2408 - 2409
  • [14] Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes
    Wang, JX
    Li, MX
    Shi, ZJ
    Li, NQ
    Gu, ZN
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1993 - 1997
  • [15] Wang JX, 2002, ELECTROANAL, V14, P225, DOI 10.1002/1521-4109(200202)14:3<225::AID-ELAN225>3.0.CO
  • [16] 2-I
  • [17] Electrocatalytic oxidation of 3,4-dihydroxyphenylacetic acid at a glassy carbon electrode modified with single-wall carbon nanotubes
    Wang, JX
    Li, MX
    Shi, ZJ
    Li, NQ
    Gu, ZN
    [J]. ELECTROCHIMICA ACTA, 2001, 47 (04) : 651 - 657
  • [18] Electrochemical sensors based on carbon nanotubes
    Zhao, Q
    Gan, ZH
    Zhuang, QK
    [J]. ELECTROANALYSIS, 2002, 14 (23) : 1609 - 1613