Carbon nanotube/teflon composite electrochemical sensors and biosensors

被引:732
作者
Wang, J [1 ]
Musameh, M [1 ]
机构
[1] New Mexico State Univ, Dept Chem, Las Cruces, NM 88003 USA
关键词
D O I
10.1021/ac030007+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication and attractive performance of carbon nanotube (CNT)/Teflon composite electrodes, based on the dispersion of CNT within a Teflon binder, are described. The resulting CNT/Teflon material brings new capabilities for electrochemical devices by combining the advantages of CNT and "bulk" composite electrodes. The electrocatalytic properties of CNT are not impaired by their association with the Teflon binder. The marked electrocatalytic activity toward hydrogen peroxide and NADH permits effective low-potential amperometric biosensing of glucose and ethanol, respectively, in connection with the incorporation of glucose oxidase and alcohol dehydrogenase/NAD(+) within the three-dimensional CNT/Teflon matrix. The accelerated electron transfer is coupled with minimization of surface fouling and surface renewability. These advantages of CNT-based composite devices are illustrated from comparison to their graphite/Teflon counterparts. The influence of the CNT loading upon the amperometric and voltammetric data, as well as the electrode resistance, is examined. SEM images offer insights into the nature of the CNT/Teflon surface. The preparation of CNT/Teflon composites overcomes a major obstacle for creating CNT-based biosensing devices and expands the scope of CNT-based electrochemical devices.
引用
收藏
页码:2075 / 2079
页数:5
相关论文
共 15 条
[1]   Carbon nanotubes - the route toward applications [J].
Baughman, RH ;
Zakhidov, AA ;
de Heer, WA .
SCIENCE, 2002, 297 (5582) :787-792
[2]   Graphite-teflon-peroxidase composite electrodes. Application to the direct determination of glucose in musts and wines [J].
del Cerro, MA ;
Cayuela, G ;
Reviejo, AJ ;
Pingarron, JM ;
Wang, J .
ELECTROANALYSIS, 1997, 9 (14) :1113-1119
[3]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[4]   Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].
Musameh, M ;
Wang, J ;
Merkoci, A ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) :743-746
[5]   Graphite-teflon composite bienzyme electrodes for the determination of cholesterol in reversed micelles.: Application to food samples [J].
Peña, N ;
Ruiz, G ;
Reviejo, AJ ;
Pingarrón, JM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1190-1195
[6]  
Rao CNR, 2001, CHEMPHYSCHEM, V2, P78, DOI 10.1002/1439-7641(20010216)2:2<78::AID-CPHC78>3.0.CO
[7]  
2-7
[8]   COMPOSITE ELECTRODES FOR ELECTROANALYSIS - PRINCIPLES AND APPLICATIONS [J].
TALLMAN, DE ;
PETERSEN, SL .
ELECTROANALYSIS, 1990, 2 (07) :499-510
[9]   GRAPHITE-TEFLON ENZYME ELECTRODE [J].
WANG, J ;
REVIEJO, AJ ;
ANGNES, L .
ELECTROANALYSIS, 1993, 5 (07) :575-579
[10]   Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes [J].
Wang, JX ;
Li, MX ;
Shi, ZJ ;
Li, NQ ;
Gu, ZN .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :1993-1997