Ion chromatography in series with conductivity detection and inductively coupled plasma-mass spectrometry for the determination of nine halogen, metalloid and non-metal species in drinking water

被引:36
作者
Dudoit, A [1 ]
Pergantis, SA [1 ]
机构
[1] Univ London Birkbeck Coll, Sch Biol & Chem Sci, London WC1H 0PP, England
关键词
D O I
10.1039/b100783l
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Ion chromatography (IC) with conductivity detection (ConD) was coupled on-line with inductively coupled plasma-mass spectrometry (ICP-MS) for the purpose of multielement speciation in drinking water. The system allows for the determination of two disinfection by-products (bromate and iodate), their precursors (bromide and iodide), two suspect carcinogenic substances that occur naturally in drinking water (arsenite and arsenate) and three common matrix anions (chloride, nitrate and sulfate). Detection limits, achieved via the direct injection of 100 muL samples, were adequate for the analysis of water intended for human consumption. ICP-MS signal stability and reduced spectroscopic interferences were observed with the use of a membrane suppressor. The IC-ConD-ICP-MS method was used For the analysis of a series of drinking water and spiked drinking water samples. In all samples analysed, bromate and arsenic levels were below the maximum levels set by the US Environmental Protection Agency and the European Commission. Average spike recoveries [+/-RSD (%)] were 101 +/- 1.5% for bromate, 96 +/- 17% for bromide, 98 +/- 2.8% for arsenic, 98 +/- 1.9% for iodate, 91 +/- 5% for iodide, 87 +/- 5.5% for chloride, 96 +/- 1.1% for nitrate and 95 +/- 1.8% for sulfate. The method was also used to monitor bromate removal from drinking water following filtration through a domestic water purification unit.
引用
收藏
页码:575 / 580
页数:6
相关论文
共 23 条
[1]
[Anonymous], 1997, EPA600R98118
[2]
Bromate removal during transition from new granular activated carbon (GAC) to biological activated carbon (BAC) [J].
Asami, M ;
Aizawa, T ;
Morioka, T ;
Nishijima, W ;
Tabata, A ;
Magara, Y .
WATER RESEARCH, 1999, 33 (12) :2797-2804
[3]
Bao ML, 1999, WATER RES, V33, P2959
[4]
Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisation [J].
Björn, E ;
Frech, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :4-11
[5]
Electrospray ion chromatography tandem mass spectrometry of oxyhalides at sub-ppb levels [J].
Charles, L ;
Pépin, D .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :353-359
[6]
Isotope dilution analysis of bromate in drinking water matrixes by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Brockhoff, CA .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :722-726
[7]
Determination of bromate in drinking waters by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Pfaff, JD ;
Brockhoff, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :261-267
[8]
Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Brockhoff, CA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) :2059-2063
[9]
Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography [J].
Diemer, J ;
Heumann, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :74-79
[10]