Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction Optical Coherence Tomography Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial

被引:140
作者
Guagliumi, Giulio [1 ]
Costa, Marco A. [2 ]
Sirbu, Vasile [1 ]
Musumeci, Giuseppe [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Mihalcsik, Laurian [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Mintz, Gary S. [3 ,4 ]
Dressler, Ovidiu [3 ,4 ]
Parise, Helen [3 ,4 ]
Maehara, Akiko [3 ,4 ]
Cristea, Ecaterina [3 ,4 ]
Lansky, Alexandra J. [3 ,4 ]
Mehran, Roxana [3 ,4 ]
Stone, Gregg W. [3 ,4 ]
机构
[1] Osped Riuniti Bergamo, Cardiovasc Dept, Div Cardiol, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Columbia Univ, Med Ctr, New York, NY USA
[4] Cardiovasc Res Fdn, New York, NY USA
关键词
myocardial infarction; angioplasty; stents; tomography; optical coherence; thrombosis; INTRAVASCULAR ULTRASOUND; NEOINTIMAL COVERAGE; THROMBOSIS; IMPLANTATION; APPOSITION; RESPONSES;
D O I
10.1161/CIRCULATIONAHA.110.963181
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The safety of drug-eluting stents in ST-segment elevation myocardial infarction (STEMI) continues to be debated. Pathological studies have demonstrated an association between uncovered struts and subsequent stent thrombosis. Optical coherence tomography can detect stent strut coverage in vivo on a micron-scale level. We therefore used optical coherence tomography to examine strut coverage in patients with STEMI treated with paclitaxel-eluting stents (PES) and bare metal stents (BMS). Methods and Results-In the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, patients with STEMI were randomized 3: 1 to PES or BMS implantation. In a formal substudy, optical coherence tomography at 13 months was performed in 118 consecutive randomized patients (89 PES, 29 BMS) in whom 188 stents were assessed (146 PES and 42 BMS). A total of 44 139 stent struts were analyzed by an independent core laboratory blinded to stent assignment. The primary prespecified end point, the percentage of uncovered stent struts per lesion at follow-up, was 1.1 +/- 2.5% in BMS lesions versus 5.7 +/- 7.0% in PES lesions (P<0.0001). Malapposed struts were observed in 0.1 +/- 0.2% of BMS lesions versus 0.9 +/- 2.1% of PES lesions (P=0.0003). Percentage net volume obstruction was 36.0 +/- 15.4% with BMS and 19.2 +/- 11.3% with PES (P<0.0001). Conclusions-In patients with STEMI undergoing primary percutaneous coronary intervention, implantation of PES as compared with BMS significantly reduces neointimal hyperplasia but results in higher rates of uncovered and malapposed stent struts as assessed by optical coherence tomography at 13-month follow-up. Further studies are required to determine the clinical significance of these findings.
引用
收藏
页码:274 / 281
页数:8
相关论文
共 33 条
[1]   Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation [J].
Awata, Masaki ;
Kotani, Jun-ichi ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Nanto, Shinsuke ;
Hori, Masatsugu ;
Nagata, Seiki .
CIRCULATION, 2007, 116 (08) :910-916
[2]   An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[3]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[4]  
Clemmensen P, 2010, AM COLL CARD 59 ANN
[5]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[6]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[7]   Vascular responses to drug eluting stents - Importance of delayed healing [J].
Finn, Aloke V. ;
Nakazawa, Gaku ;
Joner, Michael ;
Kolodgie, Frank D. ;
Mont, Erik K. ;
Gold, Herman K. ;
Virmani, Renu .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2007, 27 (07) :1500-1510
[8]   Reproducibility of quantitative optical coherence tomography for stent analysis [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Commissaris, Koen H. ;
Bezerra, Hiram ;
Gobbens, Pierre ;
Costa, Marco ;
Regar, Evelyn .
EUROINTERVENTION, 2009, 5 (02) :224-232
[9]   Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina Insights From Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Barlis, Peter ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Regar, Evelyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :445-452
[10]   Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stenting [J].
Guagliumi, Giulio ;
Sirbu, Vasile .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :237-247