Catheter-directed contrast-enhanced coronary MR angiography in swine using magnetization-prepared True-FISP

被引:18
作者
Green, JD
Omary, RA
Schirf, BE
Tang, R
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Evanston, IL 60208 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
magnetic resonance (MR); coronary vessels; interventional MR; True-FISP; MR angiography;
D O I
10.1002/mrm.10642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast-enhanced (CE) coronary magnetic resonance angiography (MRA) following intraarterial (IA) injection of contrast agent was compared using two sequences in swine: magnetization-prepared fast imaging with steady-state precession (True-FISP), and magnetization-prepared fast low-angle shot (FLASH). Thick-slice projection images were acquired with submillimeter in-plane spatial resolution (0.9 x 0.8 mm(2)). The magnetization-preparation scheme provided a clear delineation of the major coronary arteries with excellent background suppression. The Trule-FISP acquisition resulted in an increase in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) by approximately a factor of 2 over FLASH (P < 0.05). Magnetization-prepared True-FISP is a promising technique for catheter-directed CE thick-slice projection coronary MRA. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1317 / 1321
页数:5
相关论文
共 12 条
[1]   Background suppression using magnetization preparation for contrast-enhanced MR projection angiography [J].
Bos, C ;
Bakker, CJG ;
Viergever, MA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :78-87
[2]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[3]   Two- and three-dimensional MR coronary angiography with intraarterial injections of contrast agent in dogs: A feasibility study [J].
Green, JD ;
Omary, RA ;
Finn, JP ;
Chung, YC ;
Tang, R ;
Li, YZ ;
Vasireddy, S ;
Li, DB .
RADIOLOGY, 2003, 226 (01) :272-277
[4]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[5]   Intravascular magnetic resonance imaging using a loopless catheter antenna [J].
Ocali, O ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :112-118
[6]   Real-time magnetic resonance imaging-guided coronary catheterization in swine [J].
Omary, RA ;
Green, JD ;
Schirf, BE ;
Li, YZ ;
Finn, JP ;
Li, DB .
CIRCULATION, 2003, 107 (21) :2656-2659
[7]   Use of internal coils for independent and direct MR imaging-guided endovascular device tracking [J].
Omary, RA ;
Green, JD ;
Fang, WS ;
Viohl, I ;
Finn, JP ;
Li, DB .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (02) :247-254
[8]   Real-time projection MR angiography: Feasibility study [J].
Serfaty, JM ;
Atalar, E ;
Declerck, J ;
Karmakar, P ;
Quick, HH ;
Shunk, KA ;
Heldman, AW ;
Yang, XM .
RADIOLOGY, 2000, 217 (01) :290-295
[9]   Magnetic resonance-guided coronary artery stent placement in a swine model [J].
Spuentrup, E ;
Ruebben, A ;
Schaeffter, T ;
Manning, WJ ;
Günther, RW ;
Buecker, A .
CIRCULATION, 2002, 105 (07) :874-879
[10]   Dynamic coronary MR angiography and first-pass perfusion with intracoronary administration of contrast agent [J].
Tsekos, NV ;
Woodard, PK ;
Foster, GJ ;
Moustakidis, P ;
Sharp, TL ;
Herrero, P ;
Gropler, RJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (03) :311-319