Patient-controlled epidural analgesia for labor pain: effect on labor, delivery and neonatal outcome of 0.125% bupivacaine vs 0.2% ropivacaine

被引:11
作者
Evron, S
Glezerman, M
Sadan, O
Boaz, M
Ezri, T [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Edith Wolfson Med Ctr, Dept Anesthesia, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Edith Wolfson Med Ctr, Obstet Anesthesia Unit, IL-69978 Tel Aviv, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Edith Wolfson Med Ctr, Dept Obstet & Gynecol, IL-69978 Tel Aviv, Israel
[4] Tel Aviv Univ, Sackler Fac Med, Edith Wolfson Med Ctr, Epidemiol Unit, IL-69978 Tel Aviv, Israel
关键词
D O I
10.1016/S0959-289X(03)00092-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The objective was to evaluate the influence of patient-controlled epidural analgesia (PCEA) using low doses of bupivacaine vs. ropivacaine, on labor pain, motor blockade, progression of labor, delivery and neonatal outcome. This randomized double blind study included 565 parturients. All received a 5-mL/h infusion and PCEA (5-mL boluses with a 20-min lockout, maximum volume 20mL/h) of either 0.125% bupivacaine (n = 313: 165 nulliparous, 148 parous) or 0.2% ropivacaine (n = 252: 113 nulliparous, 139 parous). Pain score, lower limb motor block, sensory levels, local analgesic doses required, hemodynamic parameters, side effects and complications were assessed. Obstetric variables included cervical dilation at epidural insertion, incidence of ruptured membranes and their duration, use of oxytocin, fetal heart rate changes, duration of labor, mode and outcome of delivery, and use of invasive and non-invasive fetal monitoring. Neonatal characteristics included birth weight, Apgar scores, umbilical artery pH, serum bilirubin, hypoglycemia, need for assisted ventilation, sepsis or sepsis study, feeding difficulties and respiratory distress syndrome. Ropivacaine 0.2% was equianalgesic with 0.125% bupivacaine, but produced less motor block (P < 0.0001). There were no significant differences, however, in duration of labor, delivery type or neonatal outcome. (C) 2003 Published by Elsevier Ltd.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 31 条
[1]   Patient-controlled epidural analgesia during labor: The effects of the increase in bolus and lockout interval [J].
Bernard, JM ;
Le Roux, D ;
Vizquel, L ;
Barthe, A ;
Gonnet, JM ;
Aldebert, A ;
Benani, RM ;
Fossat, C ;
Frouin, J .
ANESTHESIA AND ANALGESIA, 2000, 90 (02) :328-332
[2]   Relative potencies of bupivacaine and ropivacaine for analgesia in labour [J].
Capogna, G ;
Celleno, D ;
Fusco, P ;
Lyons, G ;
Columb, M .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (03) :371-373
[3]   CONTINUOUS INFUSION EPIDURAL ANALGESIA DURING LABOR - A RANDOMIZED, DOUBLE-BLIND COMPARISON OF 0.0625-PERCENT BUPIVACAINE 0.0002-PERCENT FENTANYL VERSUS 0.125-PERCENT BUPIVACAINE [J].
CHESTNUT, DH ;
OWEN, CL ;
BATES, JN ;
OSTMAN, LG ;
CHOI, WW ;
GEIGER, MW .
ANESTHESIOLOGY, 1988, 68 (05) :754-759
[4]   RANDOMIZED COMPARISON OF COMBINED SPINAL-EPIDURAL AND STANDARD EPIDURAL ANALGESIA IN LABOR [J].
COLLIS, RE ;
DAVIES, DWL ;
AVELING, W .
LANCET, 1995, 345 (8962) :1413-1416
[5]   Are the new local anesthetics worth their cost? [J].
D'Angelo, R .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (06) :639-641
[6]   Epidural fentanyl produces labor analgesia by a spinal mechanism [J].
D'Angelo, R ;
Gerancher, JC ;
Eisenach, JC ;
Raphael, BL .
ANESTHESIOLOGY, 1998, 88 (06) :1519-1523
[7]   Is ropivacaine less potent than bupivacaine? [J].
D'Angelo, R ;
James, RL .
ANESTHESIOLOGY, 1999, 90 (04) :941-943
[8]   Ropivacaine 0.2% versus bupivacaine 0.1% with fentanyl:: a double blind comparison for analgesia during labour [J].
Dresner, M ;
Freeman, J ;
Calow, C ;
Quinn, A ;
Bamber, J .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (06) :826-829
[9]   A comparison of 0.0625% bupivacaine with fentanyl and 0.1% ropivacaine with fentanyl for continuous epidural labor analgesia [J].
Fernandez-Guisasola, J ;
Serrano, ML ;
Cobo, B ;
Muñoz, L ;
Plaza, A ;
Trigo, C ;
del Valle, SG .
ANESTHESIA AND ANALGESIA, 2001, 92 (05) :1261-1265
[10]  
GAMBLING DR, 1990, ANESTH ANALG, V70, P256