k-space based summary motion detection for functional magnetic resonance imaging

被引:38
作者
Caparelli, EC
Tomasi, D
Arnold, S
Chang, L
Ernst, T
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
[2] Univ Nacl Gen San Martin, Excuela Ciencia & Tecnol, RA-1651 Buenos Aires, DF, Argentina
关键词
fMRl; brain movement; motion detector; k-space data;
D O I
10.1016/S1053-8119(03)00339-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional MRI studies are very sensitive to motion; head movements of as little as I-mm translations or V rotations may cause spurious signals. An algorithm was developed that uses k-space MRI data to monitor subject motion during functional MRI time series. A k-space weighted average of squared difference between the initial scan and subsequent scans is calculated, which summarizes subject motion in a single quality parameter; however, the quality parameter cannot be used for motion correction. The evolution of this quality parameter throughout a time series indicates whether head motion is within a predetermined limit. Fifty functional MRI studies were used to calibrate the sensitivity of the algorithm, using the six rigid-body registration parameters (three translations and three rotations) from the statistical parametric mapping (SPM99) package as a reference. The average correlation coefficient between the new quality parameter and the reference value from SPM was 0.84. The simple algorithm correctly classified acceptable or excessive motion with 90% accuracy, with the remaining 10% being borderline cases. This method makes it possible to evaluate brain motion within seconds after a scan and to decide whether a study needs to be repeated. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:1411 / 1418
页数:8
相关论文
共 17 条
[1]   Ghost artifact reduction for echo planar imaging using image phase correction [J].
Buonocore, MH ;
Gao, LS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :89-100
[2]   What is the best similarity measure for motion correction in fMRI time series? [J].
Freire, L ;
Roche, A ;
Mangin, JF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (05) :470-484
[3]   Motion correction algorithms may create spurious brain activations in the absence of subject motion [J].
Freire, L ;
Mangin, JF .
NEUROIMAGE, 2001, 14 (03) :709-722
[4]  
Friston K., 1995, HUM BRAIN MAP, V2, P165, DOI DOI 10.1002/HBM.460030303
[5]   Movement-related effects in fMRI time-series [J].
Friston, KJ ;
Williams, S ;
Howard, R ;
Frackowiak, RSJ ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :346-355
[6]  
Gradshteyn I. S., 1980, TABLE INTEGRALS SERI
[7]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841
[8]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[9]  
Mathiak K, 2001, MAGNET RESON MED, V45, P167, DOI 10.1002/1522-2594(200101)45:1<167::AID-MRM1023>3.0.CO
[10]  
2-M