What is the best similarity measure for motion correction in fMRI time series?

被引:300
作者
Freire, L [1 ]
Roche, A
Mangin, JF
机构
[1] CEA, Serv Hosp Frederic Joliot, F-91401 Orsay, France
[2] FCUL, Dept Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
[3] FML, Inst Nucl Med, P-1649028 Lisbon, Portugal
[4] INRIA, Epidaure Project, Sophia Antipolis, France
[5] Univ Oxford, Med Vis Lab, Oxford OX2 7BZ, England
关键词
artifact; fMRI; motion correction; robust registration; spurious activation;
D O I
10.1109/TMI.2002.1009383
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It has been shown that the difference of squares cost function used by standard realignment packages (SENT and AIR) can lead to the detection of spurious activations, because the motion parameter estimations are biased by the activated areas. Therefore, this paper describes several experiments aiming at selecting a better similarity measure to drive functional magnetic resonance image registration. The behaviors of the Geman-McClure (GM) estimator, of the correlation ratio, and of the mutual information (MI) relative to activated areas are studied using simulated time series and actual data stemming from a 3T magnet. It is shown that these methods are more robust than the usual difference of squares measure. The results suggest also that the measures built from robust metrics like the GM estimator may be the best choice, while MI is also an interesting solution. Some more work, however, is required to compare the various robust metrics proposed in the literature.
引用
收藏
页码:470 / 484
页数:15
相关论文
共 38 条
[1]   Modeling geometric deformations in EPI time series [J].
Andersson, JLR ;
Hutton, C ;
Ashburner, J ;
Turner, R ;
Friston, K .
NEUROIMAGE, 2001, 13 (05) :903-919
[2]  
BIRN RM, 1997, P ISMRM 5 ANN M VANC, P1913
[3]   Motion correction algorithms may create spurious brain activations in the absence of subject motion [J].
Freire, L ;
Mangin, JF .
NEUROIMAGE, 2001, 14 (03) :709-722
[4]   Movement-related effects in fMRI time-series [J].
Friston, KJ ;
Williams, S ;
Howard, R ;
Frackowiak, RSJ ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :346-355
[5]   Spatial registration and normalization of images [J].
Friston, KJ ;
Ashburner, J ;
Frith, CD ;
Poline, JB ;
Heather, JD ;
Frackowiak, RSJ .
HUMAN BRAIN MAPPING, 1995, 3 (03) :165-189
[6]  
FROUIN V, 1997, NEUROIMAGE 2, V5, pS458
[7]   Characterization and correction of interpolation effects in the realignment of fMRI time series [J].
Grootoonk, S ;
Hutton, C ;
Ashburner, J ;
Howseman, AM ;
Josephs, O ;
Rees, G ;
Friston, KJ ;
Turner, R .
NEUROIMAGE, 2000, 11 (01) :49-57
[8]   ARTIFACTS DUE TO STIMULUS CORRELATED MOTION IN FUNCTIONAL IMAGING OF THE BRAIN [J].
HAJNAL, JV ;
MYERS, R ;
OATRIDGE, A ;
SCHWIESO, JE ;
YOUNG, IR ;
BYDDER, GM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :283-291
[9]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[10]   Voxel similarity measures for 3-D serial MR brain image registration [J].
Holden, M ;
Hill, DLG ;
Denton, ERE ;
Jarosz, JM ;
Cox, TCS ;
Rohlfing, T ;
Goodey, J ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) :94-102