High sequence coverage of proteins isolated from liquid separations of breast cancer cells using capillary electrophoresis-time-of-flight MS and MALDI-TOF MS mapping

被引:53
作者
Zhu, K
Kim, J
Yoo, C
Miller, FR
Lubman, DM [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Wayne State Univ, Barbara Ann Karmanos Canc Inst, Detroit, MI 48201 USA
关键词
D O I
10.1021/ac0346454
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for high sequence coverage analysis of proteins isolated from breast cancer cell lines. Intact proteins are isolated using multidimensional liquid-phase separations that permit the collection of individual protein fractions. Protein digests are then analyzed by both matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) peptide mass fingerprinting and by capillary electrophoresis-electrospray ionization (CE-ESI)-TOF MS peptide mapping. These methods can be readily interfaced to the relatively clean proteins resulting from liquid-phase fractionation of cell lysates with little sample preparation. Using combined sequence information provided by both mapping methods, 100% sequence coverage is often obtained for smaller proteins, while for larger proteins up to 75 kDa, over 90% coverage can be obtained. Furthermore, an accurate intact protein MW value (within 150 ppm) can be obtained from ESI-TOF MS. The intact MW together with high coverage sequence information provides accurate identification. More notably the high sequence coverage of CE-ESI-TOF MS together with the MS/MS information provided by the ion trap/reTOF MS elucidates posttranslational modifications, sequence changes, truncations, and isoforms that may otherwise go undetected when standard MALDI-MS peptide fingerprinting is used. This capability is critical in the analysis of human cancer cells where large numbers of expressed proteins are modified, and these modifications may play an important role in the cancer process.
引用
收藏
页码:6209 / 6217
页数:9
相关论文
共 56 条
[41]   Clinical proteomics: Translating benchside promise into bedside reality [J].
Petricoin, EF ;
Zoon, KC ;
Kohn, EC ;
Barrett, JC ;
Liotta, LA .
NATURE REVIEWS DRUG DISCOVERY, 2002, 1 (09) :683-695
[42]   High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies [J].
Premstaller, A ;
Oberacher, H ;
Walcher, W ;
Timperio, AM ;
Zolla, L ;
Chervet, JP ;
Cavusoglu, N ;
van Dorsselaer, A ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2390-+
[43]   Development and characterization of an electrospray ionization ion trap linear time-of-flight mass spectrometer [J].
Purves, RW ;
Li, L .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (10) :1085-1093
[44]   Malignant MCF10CA1 cell lines derived from premalignant human breast epithelial MCF10AT cells [J].
Santner, SJ ;
Dawson, PJ ;
Tait, L ;
Soule, HD ;
Eliason, J ;
Mohamed, AN ;
Wolman, SR ;
Heppner, GH ;
Miller, FR .
BREAST CANCER RESEARCH AND TREATMENT, 2001, 65 (02) :101-110
[45]  
Srinivas PR, 2002, CLIN CHEM, V48, P1160
[46]   Investigation of cytolysin variants by peptide mapping: enhanced protein characterization using complementary ionization and mass spectrometric techniques [J].
Stevens, SM ;
Kem, WR ;
Prokai, L .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (22) :2094-2101
[47]   Identification of proteins in complexes by solid phase microextraction multistep elution capillary electrophoresis tandem mass spectrometry [J].
Tong, W ;
Link, A ;
Eng, JK ;
Yates, JR .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2270-2278
[48]  
Vercoutter-Edouart AS, 2001, CANCER RES, V61, P76
[49]   An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation [J].
Wagner, K ;
Miliotis, T ;
Marko-Varga, G ;
Bischoff, R ;
Unger, KK .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :809-820
[50]   Monolithic capillary columns for liquid chromatography-electrospray ionization mass spectrometry in proteomic and genomic research [J].
Walcher, W ;
Oberacher, H ;
Troiani, S ;
Hölzl, G ;
Oefner, P ;
Zolla, L ;
Huber, CG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :111-125