Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing

被引:84
作者
La Rivière, PJ [1 ]
Billmire, DM [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
Poisson distributions; X-ray tomography;
D O I
10.1109/TMI.2004.838324
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a statistically principled sinogram smoothing approach for X-ray computed tomography (CT) with the intent of reducing noise-induced streak artifacts. These artifacts arise in CT when some subset of the transmission measurements capture relatively few photons because of high attenuation along the measurement lines. Attempts to reduce these artifacts have focused on the use of adaptive filters that strive to tailor the degree of smoothing to the local noise levels in the measurements. While these approaches involve loose consideration of the measurement statistics to determine smoothing levels, they do not explicitly model the statistical distributions of the measurement data. In this paper, we present an explicitly statistical approach to sinogram smoothing in the presence of photon-starved measurements. It is an extension of a nonparametric sinogram smoothing approach using penalized Poisson-likelihood functions that we have previously developed for emission tomography. Because the approach explicitly models the data statistics, it is naturally adaptive-it will smooth more variable measurements more heavily than it does less variable measurements. We find that it significantly reduces streak artifacts and noise levels without comprising image resolution.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 24 条
[1]  
[Anonymous], INFORM PROCESSING ME
[2]   Ordered subset reconstruction for x-ray CT [J].
Beekman, FJ ;
Kamphuis, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1835-1844
[3]   An iterative maximum-likelihood polychromatic algorithm for CT [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) :999-1008
[4]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99
[5]  
Green P. J., 1994, NONPARAMETRIC REGRES
[6]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[7]   An iterative approach to the beam hardening correction in cone beam CT [J].
Hsieh, J ;
Molthen, RC ;
Dawson, CA ;
Johnson, RH .
MEDICAL PHYSICS, 2000, 27 (01) :23-29
[8]   Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147
[9]  
Hsieh J., 2003, Computed tomography: principles, design, artifacts, and recent advances
[10]   Lung cancer screening: Minimum tube current required for helical CT [J].
Itoh, S ;
Ikeda, M ;
Arahata, S ;
Kodaira, T ;
Isomura, T ;
Kato, T ;
Yamakawa, K ;
Maruyama, K ;
Ishigaki, T .
RADIOLOGY, 2000, 215 (01) :175-183