The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping

被引:13
作者
Brunett, BA
Van Scyoc, JM
Schlesinger, TE
James, RB
机构
[1] Sandia Natl Labs, Livermore, CA 94551 USA
[2] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
关键词
cadmium zinc telluride; mapping; gamma-ray detectors; spectrometer; unipolar;
D O I
10.1016/S0168-9002(00)00854-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
yWe have developed a system to measure the spatial response of cadmium zinc telluride (CZT) radiation detectors. Using this system we have measured the response of several novel detector designs including several variations of the unipolar design. We have observed a wide range of energy resolution and efficiency among the different device designs. Each design has unique strengths and weaknesses which affect the device performance. In addition to design effects on performance, several instances of poor material uniformity degrading the device performance have been observed. In this paper we will discuss the spatial detector response focusing on the effects of the detector design. Where appropriate, we will also discuss the observed effects of material uniformity on device performance. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:76 / 84
页数:9
相关论文
共 12 条
[1]   Optimization criteria for coplanar-grid detectors [J].
Amman, M ;
Luke, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :205-212
[2]   CdZnTe pixel array detectors and implications for producing large volume gamma-ray spectrometers [J].
Brunett, BA ;
Van Scyoc, JM ;
James, RB ;
Schlesinger, TE .
JOURNAL OF APPLIED PHYSICS, 1999, 86 (07) :3926-3933
[3]   Fine-scale spatial response of CdZnTe radiation detectors [J].
Brunett, BA ;
Van Scyoc, JM ;
Hilton, NR ;
Lund, JC ;
James, RB ;
Schlesinger, TE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :237-242
[4]  
BRUNETT BA, 1999, SAND998215
[5]   Signals induced in semiconductor gamma-ray imaging detectors [J].
Eskin, JD ;
Barrett, HH ;
Barber, HB .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) :647-659
[6]   Position-sensitive single carrier CdZnTe detectors [J].
He, Z ;
Knoll, GF ;
Wehe, DK ;
Miyamoto, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2) :180-185
[7]   Device simulation and optimization of laterally-contacted-unipolar-nuclear detector [J].
Lee, EY ;
James, RB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01) :66-71
[8]  
LINGREN CL, 1998, RES SOC S P, V487, P263
[9]   UNIPOLAR CHARGE SENSING WITH COPLANAR ELECTRODES - APPLICATION TO SEMICONDUCTOR-DETECTORS [J].
LUKE, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :207-213