Miniaturized amperometric biosensor based on xanthine oxidase for monitoring hypoxanthine in cell culture media

被引:48
作者
Mao, LQ
Xu, F
Xu, Q
Jin, LT
机构
[1] Tokyo Inst Technol, Dept Elect Chem, Interdisciplinary Grad Sch Sci & Engn, Midori Ku, Yokohama, Kanagawa 2268502, Japan
[2] E China Normal Univ, Sch Chem & Life Sci, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
miniaturized amperometric biosensor; myocardial cell culture media; hypoxanthine;
D O I
10.1006/abio.2001.5067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fabrication and characterization of miniaturized amperometric hypoxanthine biosensors are described and demonstrated for monitoring hypoxanthine in myocardial cell culture media. The sensors are based on xanthine oxidase (XO) immobilized on carbon fiber microelectrodes (CFMEs) using a composite film of Nafion and electropolymerized phenol (PPh), Nafion was used for XO immobilization because of its film hydrophobicity, enzyme-favored environment., and electrostatic interaction with XO, which was dispersed in Nafion film by immersing the Nafion-coated CFMEs in XO solution for 5 h, PPh film was formed as an overlay on Nafion and XO-modified CFMEs via electropolymerization. Hypoxanthine was measured with the sensor by the oxidation of enzymatic reaction products, hydrogen peroxide (H2O2), and uric acid (UA) at +0.60 V (vs Ag/AgCl). The use of Nafion and PPh as a matrix for XO immobilization yields enhanced specificity, sensitivity, and linearity toward hypoxanthine. A dynamic linear range of 5.0 muM to 1.8 mM was achieved with a calculated detection limit of 1.5 muM (S/N = 3) and a sensitivity of 3.144 nA/mM. In addition, the measurement was virtually interference-free from easily oxidizable species such as UA, ascorbic acid, physiological levels of neurotransmitters, and their principal metabolites. The biosensor was used to monitor hypoxanthine accumulation in myocardial cell culture media, in which the level of extracellular hypoxanthine was found to increase with ischemic tolerance, (C) 2001 Academic Press.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 44 条
[1]   Mediated, amperometric biosensor for glucose-6-phosphate monitoring based on entrapped glucose-6-phosphate dehydrogenase, Mg2+ ions, tetracyanoquinodimethane, and nicotinamide adenine dinucleotide phosphate in carbon paste [J].
Bassi, AS ;
Tang, DQ ;
Bergougnou, MA .
ANALYTICAL BIOCHEMISTRY, 1999, 268 (02) :223-228
[2]   The calcium hypothesis of brain aging and neurodegenerative disorders: Significance in diabetic neuropathy [J].
Biessels, G ;
Gispen, WH .
LIFE SCIENCES, 1996, 59 (5-6) :379-387
[3]   Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination [J].
Carsol, MA ;
Volpe, G ;
Mascini, M .
TALANTA, 1997, 44 (11) :2151-2159
[4]   Development of a system with enzyme reactors for the determination of fish freshness [J].
Carsol, MA ;
Mascini, M .
TALANTA, 1998, 47 (02) :335-342
[5]  
Cheng Q, 1998, ANAL CHIM ACTA, V369, P245, DOI 10.1016/S0003-2670(98)00213-X
[6]   Simultaneous detection of nucleotides, nucleosides and oxidative metabolites in myocardial biopsies [J].
Childs, KF ;
Ning, XH ;
Bolling, SF .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02) :181-186
[7]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[8]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[9]   Development of an amperometric enzyme electrode biosensor for fish freshness detection [J].
Ghosh, S ;
Sarker, D ;
Misra, TN .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :58-62
[10]   AMPEROMETRIC SENSOR FOR HYPOXANTHINE AND XANTHINE BASED ON THE DETECTION OF URIC-ACID [J].
GONZALEZ, E ;
PARIENTE, F ;
LORENZO, E ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1991, 242 (02) :267-273