摘要
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-vp. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63 +/- 12 years, 73% men, with ct mean reference diameter of 2.9 +/- 0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted In a postprocedural minimal luminal diameter of 2.7 +/- 0.7 mm and a residual diameter stenosis of 17 +/- 10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-vp of 10 +/- 4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical evens at follow-vp. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:1345 / 1351
页数:7
相关论文
共 28 条
  • [11] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [12] LUMINAL LOSS AND SITE OF RESTENOSIS AFTER PALMAZ-SCHATZ CORONARY STENT IMPLANTATION
    IKARI, Y
    HARA, K
    TAMURA, T
    SAEKI, F
    YAMAGUCHI, T
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (03) : 117 - 120
  • [13] IKARI Y, 1997, AM J CARDIOL, V79, P801
  • [14] Three-year follow-up after implantation of metallic coronary-artery stents
    Kimura, T
    Yokoi, H
    Nakagawa, Y
    Tamura, T
    Kaburagi, S
    Sawada, Y
    Sato, Y
    Yokoi, H
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) : 561 - 566
  • [15] Long-term (4- to 6-year) outcome of Palmaz-Schatz stenting: Paucity of late clinical stent-related problems
    Laham, RJ
    Carrozza, JP
    Berger, C
    Cohen, DJ
    Kuntz, RE
    Baim, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) : 820 - 826
  • [16] BALLOON ANGIOPLASTY FOR TREATMENT OF IN-STENT RESTENOSIS - FEASIBILITY, SAFETY, AND EFFICACY
    MACANDER, PJ
    ROUBIN, GS
    AGRAWAL, SK
    CANNON, AD
    DEAN, LS
    BAXLEY, WA
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02): : 125 - 131
  • [17] MACDONALD RG, 1991, CIRCULATION S2, V84, P196
  • [18] Mehran R, 1997, CIRCULATION, V96, P2183
  • [19] Long-term clinical follow-up after successful repeat percutaneous intervention for stent restenosis
    Reimers, B
    Moussa, I
    Akiyama, T
    Tucci, G
    Ferraro, M
    Martini, G
    Blengino, S
    DiMario, C
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) : 186 - 192
  • [20] INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    ROUBIN, GS
    CANNON, AD
    AGRAWAL, SK
    MACANDER, PJ
    DEAN, LS
    BAXLEY, WA
    BRELAND, J
    [J]. CIRCULATION, 1992, 85 (03) : 916 - 927