Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras

被引:113
作者
Akiba, M
Chan, KP
Tanno, N
机构
[1] Japan Sci & Technol Corp, Reg Joint Res Project Yamagata Prefecture, Yamagata 9902473, Japan
[2] Yamagata Univ, Grad Program Human Sensing & Funct Senor Engn, Yonezawa, Yamagata 99278510, Japan
关键词
D O I
10.1364/OL.28.000816
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A two-dimensional heterodyne detection technique based on the frequency-synchronous detection method [Jpn. J. Appl. Phys. 39, 1194 (2000)] is demonstrated for full-field optical coherence tomography. This technique, which employs a pair of CCD cameras to detect the in-phase and quadrature components of the heterodyne signal simultaneously, offers the advantage of phase-drift suppression in interferometric measurement. Horizontal cross-sectional images are acquired at the rate of 100 frames/s in a single longitudinal scan, with a depth interval of 6 mum, making the rapid reconstruction of three-dimensional images possible. (C) 2003 Optical Society of America.
引用
收藏
页码:816 / 818
页数:3
相关论文
共 13 条
[1]   Influence of phase drift on optical coherence tomography using a CCD camera-based heterodyne detection technique [J].
Ajub M. ;
Chan K.P. ;
Tanno N. .
Optical Review, 2002, 9 (4) :170-175
[2]   Real-time, micrometer depth-resolved imaging by low-coherence reflectometry and a two-dimensional heterodyne detection technique [J].
Akiba, M ;
Chan, KP ;
Tanno, N .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2000, 39 (11B) :L1194-L1196
[3]  
Brezinski M, 2002, OPT PHOTONICS NEWS, V13, P34, DOI 10.1364/OPN.13.4.000034
[4]   Laser imaging through scattering media by enhanced heterodyne detection and speckle averaging using 2D detector array [J].
Chan, KP ;
Satori, K ;
Inaba, H .
ELECTRONICS LETTERS, 1998, 34 (11) :1101-1103
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   Optical coherence tomography and microscopy in gastrointestinal tissues [J].
Izatt, JA ;
Kulkarni, MD ;
Wang, HW ;
Kobayashi, K ;
Sivak, MV .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) :1017-1028
[7]   Video-rate three-dimensional optical coherence tomography [J].
Laubscher, M ;
Ducros, M ;
Karamata, B ;
Lasser, T ;
Salathé, R .
OPTICS EXPRESS, 2002, 10 (09) :429-435
[8]   Three dimensional OCT images from retina and skin [J].
Podoleanu, AG ;
Rogers, JA ;
Jackson, DA .
OPTICS EXPRESS, 2000, 7 (09) :292-298
[9]   Real-time optical coherence tomography of the anterior segment at 1310 nm [J].
Radhakrishnan, S ;
Rollins, AM ;
Roth, JE ;
Yazdanfar, S ;
Westphal, V ;
Bardenstein, DS ;
Izatt, JA .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1179-1185
[10]   High-speed fiber-based polarization-sensitive optical coherence tomography of in vivo human skin [J].
Saxer, CE ;
de Boer, JF ;
Park, BH ;
Zhao, YH ;
Chen, ZP ;
Nelson, JS .
OPTICS LETTERS, 2000, 25 (18) :1355-1357