摘要
A simple algorithm is presented for planar image registration and the method is applied to the simulator and portal image registration for patient setup verification in radiation therapy. Basically, the algorithm follows the concept proposed by Balter et al. [Med. Phys. 19, 329-334 (1992)], which converts the problem of open curve registration into matching a series of points along the curves. Balter's algorithm consists of three steps: (1) to determine a common starting point for each curve pair, (2) acquire two corresponding point sets along each curve, and (3) obtain a global transform matrix by matching two point sets. We integrate all three steps into one simple procedure which fits the sampled points along the intended curve pair by taking the relative path length shift as an independent fitting parameter. After being modified, the algorithm is able to take the different magnification factors of images into account, and it avoids curvature calculations. Numerical simulation as well as clinical and phantom images have been utilized to test the accuracy of the algorithm. The typical errors are less than 1 mm in translation and 1 degrees in rotation. We also made a comparison study with the chamfer method. The results of the two methods agree to within 0.5 mm in translation and 0.5 degrees in rotation. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01006-2].
引用
收藏
页码:824 / 829
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1988, IMAGE ANAL MATH MORP
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]  
BARROW HG, 1977, UNPUB P 5 INT JOINT, P659
[4]   3-DIMENSIONAL VERIFICATION OF PATIENT PLACEMENT DURING RADIOTHERAPY USING PORTAL IMAGES [J].
BIJHOLD, J .
MEDICAL PHYSICS, 1993, 20 (02) :347-356
[5]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[6]  
BORGEFORS G, 1984, UNPUB P 7 INT C PATT, P1175
[7]   Alignment of multi-segmented anatomical features from radiation therapy images by using least square fitting [J].
Cai, JL ;
Zhou, SQ ;
Hopkinson, J ;
Saxena, VA ;
Chu, J .
MEDICAL PHYSICS, 1996, 23 (12) :2069-2075
[8]   A P-THETA TECHNIQUE FOR TREATMENT VERIFICATION IN RADIOTHERAPY AND ITS CLINICAL-APPLICATIONS [J].
DING, GX ;
SHALEV, S ;
GLUCHEV, G .
MEDICAL PHYSICS, 1993, 20 (04) :1135-1143
[9]   A portal image alignment and patient setup verification procedure using moments and correlation techniques [J].
Dong, L ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04) :697-723
[10]   METHODS FOR FULLY AUTOMATED VERIFICATION OF PATIENT SET-UP IN EXTERNAL-BEAM RADIOTHERAPY WITH POLYGON SHAPED FIELDS [J].
EILERTSEN, K ;
SKRETTING, A ;
TENNVASSAS, TL .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (06) :993-1012