A simple algorithm for planar image registration in radiation therapy

被引:12
作者
Cai, JL
Chu, JCH
Saxena, VA
Lanzl, LH
机构
[1] Rush Univ, Rush Presbyterian St Lukes Med Ctr, Dept Med Phys, Chicago, IL 60612 USA
[2] Rush Univ, Rush Presbyterian St Lukes Med Ctr, Dept Radiat Oncol, Chicago, IL 60612 USA
关键词
image registration; portal images; radiation therapy;
D O I
10.1118/1.598292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A simple algorithm is presented for planar image registration and the method is applied to the simulator and portal image registration for patient setup verification in radiation therapy. Basically, the algorithm follows the concept proposed by Balter et al. [Med. Phys. 19, 329-334 (1992)], which converts the problem of open curve registration into matching a series of points along the curves. Balter's algorithm consists of three steps: (1) to determine a common starting point for each curve pair, (2) acquire two corresponding point sets along each curve, and (3) obtain a global transform matrix by matching two point sets. We integrate all three steps into one simple procedure which fits the sampled points along the intended curve pair by taking the relative path length shift as an independent fitting parameter. After being modified, the algorithm is able to take the different magnification factors of images into account, and it avoids curvature calculations. Numerical simulation as well as clinical and phantom images have been utilized to test the accuracy of the algorithm. The typical errors are less than 1 mm in translation and 1 degrees in rotation. We also made a comparison study with the chamfer method. The results of the two methods agree to within 0.5 mm in translation and 0.5 degrees in rotation. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01006-2].
引用
收藏
页码:824 / 829
页数:6
相关论文
共 25 条
[11]   OPTIMIZATION AND EVALUATION OF LANDMARK-BASED IMAGE CORRELATION [J].
ENDE, G ;
TREUER, H ;
BOESECKE, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :261-271
[12]   Core-based portal image registration for automatic radiotherapy treatment verification [J].
Fritsch, DS ;
Chaney, EL ;
Boxwala, A ;
McAuliffe, MJ ;
Raghavan, S ;
Thall, A ;
Earnhart, JRD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1287-1300
[13]  
GALL KP, 1993, MED PHYS, V20, P1153, DOI 10.1118/1.596969
[14]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677
[15]   INVESTIGATION OF AN FFT-BASED CORRELATION TECHNIQUE FOR VERIFICATION OF RADIATION TREATMENT SETUP [J].
JONES, SM ;
BOYER, AL .
MEDICAL PHYSICS, 1991, 18 (06) :1116-1125
[16]   AUTOMATED-DETERMINATION OF PATIENT SETUP ERRORS IN RADIATION-THERAPY USING SPHERICAL RADIO-OPAQUE MARKERS [J].
LAM, KL ;
TENHAKEN, RK ;
MCSHAN, DL ;
THORNTON, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1145-1152
[17]  
LAM WC, 1990, MED PHYS, V17, P554
[18]   UNFOLDING PATIENT MOTION WITH BIPLANE RADIOGRAPHS [J].
LI, SD ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1994, 21 (09) :1427-1433
[19]   A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES [J].
MEERTENS, H ;
BIJHOLD, J ;
STRACKEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :299-323
[20]   AN EVALUATION OF 2 METHODS OF ANATOMICAL ALIGNMENT OF RADIOTHERAPY PORTAL IMAGES [J].
MICHALSKI, JM ;
WONG, JW ;
BOSCH, WR ;
YAN, D ;
CHENG, A ;
GERBER, RL ;
GRAHAM, MV ;
LOW, D ;
VALICENTI, RK ;
PIEPHOFF, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05) :1199-1206