OBJECTIVES We sought to evaluate the diagnostic accuracy of a new prospectively electrocardiogram (ECG)-triggered high-pitch scan mode for coronary computed tomography angiography (CTA), which allows an effective dose of less than 1 mSv. BACKGROUND Coronary CTA provides increasingly reliable image quality, but the associated radiation exposure can be high. METHODS Seventy-five patients with suspected coronary artery disease and in sinus rhythm were screened for participation. After exclusion of 25 patients for body weight >100 kg or failure to lower heart rate to <60 beats/min, 50 patients were studied by prospectively ECG-triggered high-pitch spiral computed tomography (CT). Coronary CTA was performed using a dual-source CT system with 2 X 128 X 0.6-mm collimation, 0.28-s rotation time, a pitch of 3.4, 100-kVp tube voltage, and current of 320 mA. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within 1 cardiac cycle. Diagnostic accuracy for detection of coronary artery stenoses >= 50% diameter stenosis was determined by comparison to invasive coronary angiography. Per-patient diagnostic performance was the primary form of analysis. RESULTS In all 50 patients (34 males, 59 +/- 12 years of age), imaging was successful. For the detection of 16 patients with at least 1 coronary artery stenosis, CT demonstrated a sensitivity of 100% (95% confidence interval [CI]: 79% to 100%) and specificity of 82% (95% CI: 65% to 93%). The positive predictive value was 72% (95% CI: 49% to 89%) and the negative predictive value was 100% (95% CI: 87% to 100%). Sensitivity was 100% (95% CI: 88% to 100%) and specificity was 94% (95% CI: 89% to 97%) on a per-vessel basis. Per-segment sensitivity was 92% (95% CI: 80% to 97%), and specificity was 98% (95% CI: 96% to 98%). Mean dose-length product for coronary CTA was 54 +/- 6 mGy . cm, the effective dose was 0.76 +/- 0.08 mSv (0.64 to 0.95 mSv). CONCLUSIONS In nonobese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides high diagnostic accuracy for the detection of coronary artery stenoses. (J Am Coll Cardiol Img 2011;4:328-37) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:328 / 337
页数:10
相关论文
共 41 条
[1]
ABDULLA J, 2010, INT J CARDIOVAS 0612
[2]
Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[3]
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[4]
Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease [J].
Achenbach, Stephan ;
Ropers, Ulrike ;
Kuettner, Axel ;
Anders, Katharina ;
Pflederer, Tobias ;
Komatsu, Sei ;
Bautz, Werner ;
Daniel, Werner G. ;
Ropers, Dieter .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) :177-186
[5]
Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Goetti, Robert ;
Plass, Andre ;
Scheffel, Hans ;
Feuchtner, Gudrun ;
Falk, Volkmar ;
Marincek, Borut ;
Leschka, Sebastian .
HEART, 2010, 96 (12) :933-938
[6]
Bongartz G., 2004, Contract number FIGM-CT2000-20078-CT-TIP
[7]
Prognostic Value of 64-Slice Cardiac Computed Tomography Severity of Coronary Artery Disease, Coronary Atherosclerosis, and Left Ventricular Ejection Fraction [J].
Chow, Benjamin J. W. ;
Wells, George A. ;
Chen, Li ;
Yam, Yeung ;
Galiwango, Paul ;
Abraham, Arun ;
Sheth, Tej ;
Dennie, Carole ;
Beanlands, Rob S. ;
Ruddy, Terrence D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) :1017-1028
[8]
Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[9]
Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Reiber, Johannes H. C. ;
Boersma, Eric ;
Schalij, Martin J. ;
Spano, Fabrizio ;
Jukema, J. Wouter ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (15) :1908-1915
[10]
Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation [J].
Dewey, Marc ;
Zimmermann, Elke ;
Deissenrieder, Florian ;
Laule, Michael ;
Duebel, Hans-Peter ;
Schlattmann, Peter ;
Knebel, Fabian ;
Rutsch, Wolfgang ;
Hamm, Bernd .
CIRCULATION, 2009, 120 (10) :867-875