Phase-based regional oxygen metabolism (PROM) using MRI

被引:85
作者
Fan, Audrey P. [1 ,3 ]
Benner, Thomas [2 ]
Bolar, Divya S. [1 ,2 ,3 ]
Rosen, Bruce R. [2 ,3 ]
Adalsteinsson, Elfar [1 ,2 ,3 ]
机构
[1] MIT, Elect Res Lab, Dept Elect Engn & Comp Sci, Magnet Resonance Imaging Grp, Cambridge, MA 02139 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[3] Harvard MIT Hlth Sci & Technol, Cambridge, MA USA
关键词
cerebral metabolic rate of oxygen; cerebral venous oxygen saturation; cerebral blood flow; MR susceptometry; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; MAGNETIC-SUSCEPTIBILITY; FIELD INHOMOGENEITY; RELAXATION-TIME; CONSUMPTION; VALIDATION; SATURATION; ACCURACY; QUANTIFICATION;
D O I
10.1002/mrm.23050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Venous oxygen saturation (Yv) in cerebral veins and the cerebral metabolic rate of oxygen (CMRO2) are important indicators for brain function and disease. Although MRI has been used for global measurements of these parameters, currently there is no recognized technique to quantify regional Yv and CMRO2 using noninvasive imaging. This article proposes a technique to quantify CMRO2 from independent MRI estimates of Yv and cerebral blood flow. The approach uses standard gradient-echo and arterial spin labeling acquisitions to make these measurements. Using MR susceptometry on gradient-echo phase images, Yv was quantified for candidate vein segments in gray matter that approximate a long cylinder parallel to the main magnetic field. Local cerebral blood flow for the identified vessel was determined from a corresponding region in the arterial spin labeling perfusion map. Fick's principle of arteriovenous difference was then used to quantify CMRO2 locally around each vessel. Application of this method in young, healthy subjects provided gray matter averages of 59.6% +/- 2.3% for Yv, 51.7 +/- 6.4 mL/100 g/min for cerebral blood flow, and 158 +/- 18 mu ol/100 g/min for CMRO2 (mean +/- SD, n = 12), which is consistent with values previously reported by positron emission tomography and MRI. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:669 / 678
页数:10
相关论文
共 48 条
[1]  
Bolar DS, 2009, P 17 ANN M ISMRM HON, P6050
[2]   An optimised framework for reconstructing and processing MR phase images [J].
Chen, Zhaolin ;
Johnston, Leigh A. ;
Kwon, Dae Hyuk ;
Oh, Se Hong ;
Cho, Zang-Hee ;
Egan, Gary F. .
NEUROIMAGE, 2010, 49 (02) :1289-1300
[3]  
CLARK MR, 1989, ANN NY ACAD SCI, V565, P284, DOI 10.1111/j.1749-6632.1989.tb24176.x
[4]   Calibrated functional MRI: Mapping the dynamics of oxidative metabolism [J].
Davis, TL ;
Kwong, KK ;
Weisskoff, RM ;
Rosen, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1834-1839
[5]   Quantitative Susceptibility Map Reconstruction from MR Phase Data Using Bayesian Regularization: Validation and Application to Brain Imaging [J].
de Rochefort, Ludovic ;
Liu, Tian ;
Kressler, Bryan ;
Liu, Jing ;
Spincemaille, Pascal ;
Lebon, Vincent ;
Wu, Jianlin ;
Wang, Yi .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (01) :194-206
[6]   Cerebral blood flow, blood volume, and oxygen metabolism dynamics in human visual and motor cortex as measured by whole-brain multi-modal magnetic resonance imaging [J].
Donahue, Manus J. ;
Blicher, Jakob U. ;
Ostergaard, Leif ;
Feinberg, David A. ;
MacIntosh, Bradley J. ;
Miller, Karla L. ;
Guenther, Matthias ;
Jezzard, Peter .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (11) :1856-1866
[7]   High-field MRI of brain cortical substructure based on signal phase [J].
Duyn, Jeff H. ;
van Gelderen, Peter ;
Li, Tie-Qiang ;
de Zwart, Jacco A. ;
Koretsky, Alan P. ;
Fukunaga, Masaki .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (28) :11796-11801
[8]   MR susceptometry for measuring global brain oxygen extraction [J].
Fernández-Seara, MA ;
Techawiboonwong, A ;
Detre, JA ;
Wehrli, FW .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :967-973
[9]   Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T [J].
Fernández-Seara, MA ;
Wang, Z ;
Wang, JJ ;
Rao, HY ;
Guenther, M ;
Feinberg, DA ;
Detre, JA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1241-1247
[10]   Organ-tissue mass measurement allows modeling of REE and metabolically active tissue mass [J].
Gallagher, D ;
Belmonte, D ;
Deurenberg, P ;
Wang, ZM ;
Krasnow, N ;
Pi-Sunyer, FX ;
Heymsfield, SB .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 1998, 275 (02) :E249-E258