Analysis of antisense oligonucleotides by capillary electrophoresis, gel-slab electrophoresis, and HPLC: A comparison

被引:34
作者
Gelfi, C
Perego, M
Morelli, S
Nicolin, A
Righetti, PG
机构
[1] CNR,ITBA,I-20133 MILAN,ITALY
[2] UNIV CALABRIA,DEPT CELL BIOL,FAC SCI,RENDE,COSENZA,ITALY
[3] UNIV MILAN,DEPT PHARMACOL,MILAN,ITALY
来源
ANTISENSE & NUCLEIC ACID DRUG DEVELOPMENT | 1996年 / 6卷 / 01期
关键词
D O I
10.1089/oli.1.1996.6.47
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Three techniques are evaluated for assessing the purity of synthetic oligodeoxyribonucleotides: reversed phase high-performance liquid chromatography (RP-HPLC), polyacrylamide gel-slab electrophoresis (PAGE), and capillary zone electrophoresis in highly concentrated (18% T) entangled polymer networks (CZE), RP-HPLC does not seem to be able to discriminate and resolve the spectrum of failed sequences expected to accompany an oligonucleotide of a given length, The purity data, as given try the manufacturer, are most often close to 100%, PAGE in 20% T matrices, followed by ethidium bromide staining, gives a good resolution of failure sequences and purity assessments decidedly more realistic, CZE in 18% liquid polyacrylamide is able to resolve to baseline all shorter fragments and to give a precise evaluation of the amount of impurities, based on the intrinsic DNA absorbance at 254 nm, Most of the 18 mer oligonucleotides (and of their phosphorothioate derivatives) analyzed by us, as supplied by three different manufacturers, were found to be contaminated by a spectrum of failed and truncated sequences, ranging in size from 7 mer to 17 mer, The purity data rarely exceeded 80% and most often were of the order of 60%-70%, Conditions for a good routine performance of the CZE technique are described.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 29 条
[21]  
NEITZEL H, 1991, CLIN GENET, V39, P97
[22]   CALIBRATION OF POLYACRYLAMIDE-GEL COLUMNS FOR THE SEPARATION OF OLIGONUCLEOTIDES BY CAPILLARY ELECTROPHORESIS [J].
PAULUS, A ;
GASSMANN, E ;
FIELD, MJ .
ELECTROPHORESIS, 1990, 11 (09) :702-708
[23]   DNA DIGEST ANALYSIS WITH CAPILLARY ELECTROPHORESIS [J].
PAULUS, A ;
HUSKEN, D .
ELECTROPHORESIS, 1993, 14 (1-2) :27-35
[24]   ANALYSIS OF OLIGONUCLEOTIDES BY CAPILLARY GEL-ELECTROPHORESIS [J].
PAULUS, A ;
OHMS, JI .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :113-123
[25]   ISOELECTRIC-FOCUSING OF PEPTIDES [J].
RIGHETTI, PG ;
CHILLEMI, F .
JOURNAL OF CHROMATOGRAPHY, 1978, 157 (SEP) :243-251
[26]  
RIGHETTI PG, 1996, CRC SER ANAL BIOTECH, P431
[27]  
SLIGHTOM JL, 1992, BIOTECHNIQUES, V13, P94
[28]   MONITORING AND ANALYSIS OF ANTISENSE DNA BY HIGH-PERFORMANCE CAPILLARY GEL-ELECTROPHORESIS [J].
VILENCHIK, M ;
BELENKY, A ;
COHEN, AS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 663 (01) :105-113
[29]   GENE INHIBITION USING ANTISENSE OLIGODEOXYNUCLEOTIDES [J].
WAGNER, RW .
NATURE, 1994, 372 (6504) :333-335