Refractive-index-mismatch induced aberrations in single-photon and two-photon microscopy and the use of aberration correction

被引:75
作者
Booth, MJ [1 ]
Wilson, T [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
关键词
confocal microscopy; two-photon microscopy; fluorescence; aberration correction;
D O I
10.1117/1.1382808
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We examine the effects of aberrations induced by a refractive index mismatch on the signal level and resolution of single-photon (1 - p) and two-photon (2 - p), conventional and confocal scanning microscopes. In particular, we consider the aberrations introduced by an interface between oil/glass and water. Resolution is defined in terms of enclosed fluorescence, rather than full-width half-maximum, revealing more useful information for heavily aberrated point spread functions (PSFs). It is shown that, at large focusing depths, the resolution of 2 - p conventional and 1 - p confocal microscopes are almost identical. The benefits of aberration correction are examined by removing Zernike aberration modes. With aberration correction, the best resolution is found for 1 - p confocal and 2-p confocal modes. An approximation based upon geometrical optics is also introduced which shows that the axial resolution of heavily aberrated PSFs is roughly proportional to focusing depth. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 1990, CONFOCAL MICROSCOPY
[2]   Aberration correction for confocal imaging in refractive-index-mismatched media [J].
Booth, MJ ;
Neil, MAA ;
Wilson, T .
JOURNAL OF MICROSCOPY, 1998, 192 :90-98
[3]   Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimens [J].
de Grauw, GJ ;
Vroom, JM ;
van der Voort, HTM ;
Gerritsen, HC .
APPLIED OPTICS, 1999, 38 (28) :5995-6003
[4]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[5]  
GIBSON SF, 1991, J OPT SOC AM A, V8, P1601, DOI 10.1364/JOSAA.8.001601
[6]   COMPARISON OF 3-DIMENSIONAL IMAGING PROPERTIES BETWEEN 2-PHOTON AND SINGLE-PHOTON FLUORESCENCE MICROSCOPY [J].
GU, M ;
SHEPPARD, CJR .
JOURNAL OF MICROSCOPY-OXFORD, 1995, 177 :128-137
[7]  
Gu M., 1996, Principles of Three-Dimensional Imaging in Confocal Microscopes
[8]   ABERRATIONS IN CONFOCAL FLUORESCENCE MICROSCOPY INDUCED BY MISMATCHES IN REFRACTIVE-INDEX [J].
HELL, S ;
REINER, G ;
CREMER, C ;
STELZER, EHK .
JOURNAL OF MICROSCOPY, 1993, 169 :391-405
[9]   REFRACTIVE-INDEX-INDUCED ABERRATIONS IN 2-PHOTON CONFOCAL FLUORESCENCE MICROSCOPY [J].
JACOBSEN, H ;
HANNINEN, P ;
SOINI, E ;
HELL, SW .
JOURNAL OF MICROSCOPY-OXFORD, 1994, 176 :226-230
[10]   Multiphoton microscopy in life sciences [J].
König, K .