Minimally invasive imageless computer-navigated knee surgery

被引:15
作者
Chandrasekaran, Sivashankar [1 ,2 ]
Molnar, Robert B. [1 ,2 ]
机构
[1] Sydney Orthopaed Trauma, Bondi Jct 1355, Australia
[2] Sutherland Hosp, Dept Orthopaed Surg, Sutherland, NSW, Australia
关键词
total knee arthroplasty; computer-assisted surgery; minimally invasive surgery; coronal; alignment; learning curve; blood loss;
D O I
10.1016/j.arth.2007.05.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The combination of imageless computer-aided surgery (CAS) and minimally invasive Surgery (MIS) for total knee arthroplasty (TKA) has not been reported. This study presents the initial 30 procedures in which imageless CAS was combined with MIS for TKA by the senior author. Coronal alignment of femoral and tibial components with respect to the mechanical axis of the lower limb was measured when patients could achieve full extension. Component position was acceptable for all implants. The mean coronal tibia] alignment was 90.35 degrees (range, 88 degrees-93 degrees) and mean coronal femoral alignment 90.10 degrees (range, 88 degrees-93 degrees) to the mechanical axis. Tourniquet time averaged 90 minutes (range, 60-118 minutes). There was no significant reduction in tourniquet time with increasing familiarity with the technique. Our results demonstrate that CAS combined with MIS for TKA maintains the accuracy of component alignment despite the minimally invasive approach. These initial results demonstrate no significant learning curve associated with the technique.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 20 条
[1]
Computed tomography-based navigation for hip, knee, and spine surgery [J].
Amiot, LP ;
Poulin, F .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (421) :77-86
[2]
Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[3]
Bäthis H, 2004, ORTHOPEDICS, V27, P476
[4]
Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[5]
Minimally invasive total knee arthroplasty: a 10-feature evolutionary approach [J].
Bonutti, PM ;
Mont, MA ;
Kester, MA .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (02) :217-+
[6]
DALBURY DF, 1999, J ARTHROPLASTY, V14, P33
[7]
Mini-incision total knee arthroplasty can increase risk of component malalignment [J].
Dalury, DF ;
Dennis, DA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :77-81
[8]
DAUHRESSE F, 2005, ACTA ORTHOP BELG, V71, P710
[9]
Computer-assisted navigation increases precision of component placement in total knee arthroplasty [J].
Haaker, RG ;
Stockheim, M ;
Kamp, M ;
Proff, G ;
Breitenfelder, J ;
Ottersbach, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) :152-159
[10]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714