Solar blind chemically vapor deposited diamond detectors for vacuum ultraviolet pulsed light-source characterization

被引:68
作者
Foulon, F [1 ]
Bergonzo, P
Borel, C
Marshall, RD
Jany, C
Besombes, L
Brambilla, A
Riedel, D
Museur, L
Castex, MC
Gicquel, A
机构
[1] CEA Saclay, LETI, DEIN, SPE, F-91191 Gif Sur Yvette, France
[2] Univ Paris 13, Phys Lasers Lab, F-93430 Villetaneuse, France
[3] Univ Paris 13, Lab Ingn Mat Hautes Press, CNRS, F-93430 Villetaneuse, France
关键词
D O I
10.1063/1.368782
中图分类号
O59 [应用物理学];
学科分类号
摘要
A major difficulty in characterizing vacuum ultraviolet (VUV) radiation produced by harmonic generation or four-wave sum frequency mixing arises in differentiating between the desired VUV signal and the remaining fundamental pump laser beam. To overcome this problem, visible and near UV blind VUV detectors, made from natural and synthetic diamond, have been developed. Such detectors have been used to characterize coherent VUV pulses (lambda = 125 nm, pulse duration at full width half maximum (FWHM) tau(FWHM)similar to 7 ns) generated by resonance-enhanced four-wave sum mixing in mercury vapor. They allow full characterization of the intensity profile of the VUV pulses, without any significant parasitic signal from simultaneous stray light irradiation at lambda = 313 nm. Detectors were fabricated exhibiting response times of less than 70 ps at FWHM, corresponding to the lowest response time obtainable with a 7 GHz bandwidth single-shot oscilloscope. (C) 1998 American Institute of Physics. [S0021-8979(98)05520-0].
引用
收藏
页码:5331 / 5336
页数:6
相关论文
共 26 条
[1]   Polarization of high-order harmonics [J].
Antoine, P ;
Carre, B ;
LHuillier, A ;
Lewenstein, M .
PHYSICAL REVIEW A, 1997, 55 (02) :1314-1324
[2]  
BACHMANN PK, 1988, MRS S P EA, V15, P99
[3]   MICROPHOTOLUMINESCENCE AND RAMAN-SCATTERING STUDY OF DEFECT FORMATION IN DIAMOND FILMS [J].
BERGMAN, L ;
STONER, BR ;
TURNER, KF ;
GLASS, JT ;
NEMANICH, RJ .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (08) :3951-3957
[4]  
ENKEVORT WJP, 1992, J PHYS-CONDENS MAT, V4, P2361
[5]   CVD diamond detectors for radiation pulse characterisation [J].
Foulon, F ;
Bergonzo, P ;
Jany, C ;
Gicquel, A ;
Pochet, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :42-45
[6]   CVD diamond photoconductors for picosecond radiation pulse characterisation [J].
Foulon, F ;
Bergonzo, P ;
Jany, C ;
Gicquel, A ;
Pochet, T .
DIAMOND AND RELATED MATERIALS, 1996, 5 (6-8) :732-736
[7]   DIAMOND DEPOSITION IN A BELL-JAR REACTOR - INFLUENCE OF THE PLASMA AND SUBSTRATE PARAMETERS ON THE MICROSTRUCTURE AND GROWTH-RATE [J].
GICQUEL, A ;
ANGER, E ;
RAVET, MF ;
FABRE, D ;
SCATENA, G ;
WANG, ZZ .
DIAMOND AND RELATED MATERIALS, 1993, 2 (2-4) :417-424
[8]   SPECTROSCOPIC ANALYSIS AND CHEMICAL-KINETICS MODELING OF A DIAMOND DEPOSITION PLASMA REACTOR [J].
GICQUEL, A ;
HASSOUNI, K ;
FARHAT, S ;
BRETON, Y ;
SCOTT, CD ;
LEFEBVRE, M ;
PEALAT, M .
DIAMOND AND RELATED MATERIALS, 1994, 3 (4-6) :581-586
[9]   OBSERVATION OF PARAMETRIC AMPLIFICATION WITH A FEMTOSECOND VACUUM-ULTRAVIOLET 4-WAVE DIFFERENCE-FREQUENCY MIXING SOURCE [J].
GLOWNIA, JH ;
GNASS, DR ;
SOROKIN, PP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1994, 11 (12) :2427-2433
[10]   New developments in photoconductive detectors (invited) [J].
Han, S .