Serum ion level after metal-on-metal THA in patients with renal failure

被引:42
作者
Hur, Chang Ich [1 ]
Yoon, Taek Rim [1 ]
Cho, Sang Gwon [1 ]
Song, Eun Kyoo [1 ]
Seon, Jong Keun [1 ]
机构
[1] Chonnam Natl Univ, Sch Med, Chonnam Natl Univ Hwasun Hosp, Ctr Joint Dis,Dept Orthopaed, Hwasun 519809, Jeonnam, South Korea
关键词
D O I
10.1007/s11999-007-0093-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We retrospectively reviewed cementless THAs with metal-on-metal bearings in five patients with chronic renal failure and investigated the relations between renal failure and elevated serum cobalt and chromium levels and the side effects of these elevations. Serum cobalt and chromium levels were measured by atomic absorption spectrophotometry at a minimum followup of 2.7 years (mean, 3.9 years; range, 2.7-6.2 years) in five patients with chronic renal failure and in six patients with normal renal function after THA. Mean serum cobalt concentration was 12.5 mu g/L in patients with chronic renal failure; this was more than 100-fold higher than in patients with the same prosthesis type and similar followup period, but with no known renal disease. However, the mean serum chromium concentration was 5.1 mu g/L, which was within the normal range in all I I study patients. Side effects related to elevation of serum cobalt or serum chromium concentration were not identified and overall clinical results were good 4 years after surgery. The serum cobalt level was higher in patients with chronic renal failure. Longer followup is necessary to determine any clinical effects.
引用
收藏
页码:696 / 699
页数:4
相关论文
共 14 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? [J].
Back, DL ;
Young, AA ;
Shimmin, AJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) :177-181
[3]
Metal-on-metal bearing with THA and chronic renal failure. [J].
Brodner, V ;
Grohs, JG ;
Bitzan, P ;
Meisinger, V ;
Kovarik, J ;
Kotz, R .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05) :425-429
[4]
Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[5]
The rationale for metal-on-metal total hip arthroplasty [J].
Cuckler, JM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :132-136
[6]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]
Total hip arthroplasty with use of the metasul metal-on-metal articulation - Four to seven-year results [J].
Dorr, LD ;
Wang, ZI ;
Longjohn, DB ;
Dubois, B ;
Murken, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06) :789-798
[8]
Engh CA., 1990, CLIN ORTHOP RELAT R, V257, P107
[9]
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses [J].
Heisel, C ;
Silva, M ;
Skipor, AK ;
Jacobs, JJ ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04) :781-787
[10]
Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements [J].
Lhotka, C ;
Szekeres, T ;
Steffan, I ;
Zhuber, K ;
Zweymüller, K .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (02) :189-195