Optimization and validation of a rapid high-resolution T1-w 3D FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness

被引:81
作者
Glaser, C
Faber, S
Eckstein, F
Fischer, H
Springer, V
Heudorfer, L
Stammberger, T
Englmeier, KH
Reiser, M
机构
[1] Univ Munich, Inst Klin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Anat Anstalt, Musculoskeletal Res Grp, D-80336 Munich, Germany
[3] GSF Neuherberg Ingolstadter, Medis Inst, D-85764 Oberschleissheim, Germany
[4] Fa Siemens, Erlangen, Germany
关键词
cartilage; quantification; MRI; osteoarthritis; follow up;
D O I
10.1016/S0730-725X(01)00292-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In view of follow up. survey and development of therapeutic strategies for osteoarthritis where cartilage deterioration plays an important role, a non invasive, reliable and quantitative assessment of the articular cartilage is desirable. The currently available high resolution T-1-weighted (T1-w) 3D FLASH pulse sequences with frequency selective fat suppression are very time consuming. We have I)optimized a high resolution T1-w 3D FLASH water excitation (WE) sequence for short acquisition time and cartilage visualization, and 2) validated this sequence for cartilage volume and thickness quantification. The spectral fat presaturation was replaced by selective water excitation. The flip angle of the WE sequence was optimized for the contrast to noise (C/N-cart) ratio of cartilage. Sagittal datasets (voxel size: 0.31 x 0.31 x 2 mm(3)) of the knees of nine healthy volunteers were acquired both, with the 3D FLASH WE (17.2/6.6/30 degrees) sequence (WE) and a previously validated 3D FLASH fat saturated (42/11/30 degrees) sequence (FS). For validation of the WE sequence, cartilage volume, mean and maximal cartilage thickness of the two sequences were compared. Reproducibility was assessed by calculating the coefficient of variation (COV %) of 4 consecutive WE data sets in the volunteers. The acquisition rime was reduced from 16 ' 30 " (FS) down to 7 ' 14 " for the WE sequence. Image contrast and visualization of the cartilage was very similar, but delineation of the basal layer of the cartilage was slightly improved with the WE sequence. A flip angle of 30 degrees provided the best C/N-cart ratios (WE). Reproducibility (COV) was between 1.9 and 5.9%. Cartilage volume and thickness agreed within 4% between FS and WE sequence. The WE sequence allows for rapid, valid and reproducible quantification of articular cartilage volume and thickness, prerequisites for follow-up examinations. The reduced acquisition time (50% of FS) enables routine clinical application and thus may contribute to a broader assessment of osteoarthritis. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 48 条
  • [1] TREATMENT OF DEEP CARTILAGE DEFECTS IN THE KNEE WITH AUTOLOGOUS CHONDROCYTE TRANSPLANTATION
    BRITTBERG, M
    LINDAHL, A
    NILSSON, A
    OHLSSON, C
    ISAKSSON, O
    PETERSON, L
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (14) : 889 - 895
  • [2] SEVERITY OF ARTICULAR-CARTILAGE ABNORMALITY IN PATIENTS WITH OSTEOARTHRITIS - EVALUATION WITH FAST SPIN-ECHO MR VS ARTHROSCOPY
    BRODERICK, LS
    TURNER, DA
    RENFREW, DL
    SCHNITZER, TJ
    HUFF, JP
    HARRIS, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 99 - 103
  • [3] Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging
    Brossmann, J
    Frank, LR
    Pauly, JM
    Boutin, RD
    Pedowitz, RA
    Haghighi, P
    Resnick, D
    [J]. RADIOLOGY, 1997, 203 (02) : 501 - 507
  • [4] OSTEOARTHRITIS OF THE KNEE - COMPARISON OF RADIOGRAPHY, CT, AND MR IMAGING TO ASSESS EXTENT AND SEVERITY
    CHAN, WP
    LANG, P
    STEVENS, MP
    SACK, K
    MAJUMDAR, S
    STOLLER, DW
    BASCH, C
    GENANT, HK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) : 799 - 806
  • [5] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [6] Eckstein F, 1998, CLIN ORTHOP RELAT R, P137
  • [7] Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)
    Eckstein, F
    Gavazzeni, A
    Sittek, H
    Haubner, M
    Losch, A
    Milz, S
    Englmeier, KH
    Schulte, E
    Putz, R
    Reiser, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 256 - 265
  • [8] Quantitative relationships of normal cartilage volumes of the human knee joint - assessment by magnetic resonance imaging
    Eckstein, F
    Winzheimer, M
    Westhoff, J
    Schnier, M
    Haubner, M
    Englmeier, KH
    Reiser, M
    Putz, R
    [J]. ANATOMY AND EMBRYOLOGY, 1998, 197 (05): : 383 - 390
  • [9] Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging
    Eckstein, F
    Adam, C
    Sittek, H
    Becker, C
    Milz, S
    Schulte, E
    Reiser, M
    Putz, R
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (03) : 285 - 289
  • [10] Magnetic resonance chondro-crassometry (MR CCM): A method for accurate determination of articular cartilage thickness
    Eckstein, F
    Sittek, H
    Gavazzeni, A
    Schulte, E
    Milz, S
    Kiefer, B
    Reiser, M
    Putz, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 89 - 96