A radially symmetric measurement chamber for electronic noses

被引:22
作者
Di Francesco, F
Falcitelli, M
Marano, L
Pioggia, G
机构
[1] CNR, Inst Clin Physiol, I-56100 Pisa, Italy
[2] TEA Ambiente Srl, I-56127 Pisa, Italy
[3] Univ Pisa, Interdept Res Ctr E Piaggio, I-56126 Pisa, Italy
关键词
measurement chamber; sensors; electronic nose; electronic tongue;
D O I
10.1016/j.snb.2004.06.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A measurement chamber for the dynamic exposure of a sensor array to gaseous or liquid samples is presented. The device has been designed to optimise sensor response signals in terms of stability, reproducibility, response time and amplitude. This chamber has a radially symmetric flow splitter, which allows homogeneous flow conditions with low velocity gradients, and avoids significant recirculating zones and stagnant volumes. These characteristics, together with the fact that sample paths from the inlet to the sensors and from the sensors to the outlet have the same length, guarantee that all sensors are always exposed to the same chemical sample under the same experimental conditions. Through mathematical models, the introduction of a tracer in the form of a square wave concentration signal was simulated, and the effects of the working tolerances of the device main component on flow conditions were discussed. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 19 条
[11]   A numerical model of nasal odorant transport for the analysis of human olfaction [J].
Keyhani, K ;
Scherer, PW ;
Mozell, MM .
JOURNAL OF THEORETICAL BIOLOGY, 1997, 186 (03) :279-301
[12]   An investigation into the use of electrochromic polymers in optical fibre gas sensors [J].
Kondratowicz, B ;
Narayanaswamy, R ;
Persaud, KC .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :138-144
[13]   Solution-based analysis of multiple analytes by a sensor array: Toward the development of an "electronic tongue" [J].
Lavigne, JJ ;
Savoy, S ;
Clevenger, MB ;
Ritchie, JE ;
McDoniel, B ;
Yoo, SJ ;
Anslyn, EV ;
McDevitt, JT ;
Shear, JB ;
Neikirk, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (25) :6429-6430
[14]   Influence of gaseous species transport on the response of solid state gas sensors within enclosures [J].
Lezzi, AM ;
Beretta, GP ;
Comini, E ;
Faglia, G ;
Galli, G ;
Sberveglieri, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :144-150
[15]   Electronic noses: specify or disappear [J].
Mielle, P ;
Marquis, F ;
Latrasse, C .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :287-294
[16]   ANALYSIS OF DISCRIMINATION MECHANISMS IN THE MAMMALIAN OLFACTORY SYSTEM USING A MODEL NOSE [J].
PERSAUD, K ;
DODD, G .
NATURE, 1982, 299 (5881) :352-355
[17]  
Proctor DF, 1983, NASAL TUMORS ANIMALS, V1, P1
[18]  
Swift D.L., 1977, RESP DEFENSE MECH, P63
[19]  
*VDI, 3881 VDI