Hyperpolarized 13C MR angiography using TrueFISP

被引:103
作者
Svensson, J [1 ]
Månsson, S
Johansson, E
Petersson, JS
Olsson, LE
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Radiat Phys, SE-20502 Malmo, Sweden
[2] Lund Univ, Malmo Univ Hosp, Dept Expt Res, SE-20502 Malmo, Sweden
[3] Univ Lund Hosp, Dept Radiat Phys, S-22185 Lund, Sweden
[4] Amersham Hlth R&D AB, MEDEON, Malmo, Sweden
关键词
C-13; hyperpolarize; hyperpolarization; angiography; contrast medium;
D O I
10.1002/mrm.10530
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A C-13-enriched water-soluble compound (bis-1,1-(hydroxymethyl)-1-C-13-cyclopropane-D-8), with a C-13-concentration of approximately 200 mM, was hyperpolarized to similar to15% using dynamic nuclear polarization, and then used as a contrast medium (CM) for contrast-enhanced magnetic resonance angiography (CE-MRA). The long relaxation times (in vitro: T-1 approximate to 82 s, T-2 approximate to 18 s; in vivo: T-1 approximate to 38 s, T-2 approximate to 1.3 s) are ideal for steady-state free precession (SSFP) imaging with a true fast imaging and steady precession (trueFISP) pulse sequence. It was shown both theoretically and experimentally that the optimal flip angle was 180degrees. CE-MRA was performed in four anesthetized live rats after intravenous injection of 3 ml CM. The angiograms covered the thoracic/abdominal region in two of the animals, and the head-neck region in the other two. Fifteen consecutive images were acquired in each experiment, with a flip-back pulse at the end of each image acquisition. In the angiograms, the vena cava (SNR approximate to 240), aorta, renal arteries, carotid arteries (SNR approximate to 75), jugular veins, and several other vessels were visible. The SNR in the cardiac region was 500. Magnetization was preserved from one image acquisition to the next using the flip-back technique (SNRcardiac approximate to 10 in the 15th image). (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:256 / 262
页数:7
相关论文
共 35 条
[1]   NMR of laser-polarized xenon in human blood [J].
Bifone, A ;
Song, YQ ;
Seydoux, R ;
Taylor, RE ;
Goodson, BM ;
Pietrass, T ;
Budinger, TF ;
Navon, G ;
Pines, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (23) :12932-12936
[2]   Vascular and perfusion imaging using encapsulated laser-polarized helium [J].
Callot, V ;
Canet, E ;
Brochot, J ;
Berthezène, Y ;
Viallon, M ;
Humblot, H ;
Briguet, A ;
Tournier, H ;
Crémillieux, Y .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2001, 12 (01) :16-22
[3]   MR perfusion imaging using encapsulated laser-polarized 3He [J].
Callot, V ;
Canet, E ;
Brochot, J ;
Viallon, M ;
Humblot, H ;
Briguet, A ;
Tournier, H ;
Crémillieux, Y .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :535-540
[4]   In vivo magnetic resonance vascular imaging using laser-polarized 3He microbubbles [J].
Chawla, MS ;
Chen, XJ ;
Möller, HE ;
Cofer, GP ;
Wheeler, CT ;
Hedlund, LW ;
Johnson, GA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (18) :10832-10835
[5]  
Chawla MS, 2000, MAGN RESON MED, V43, P440, DOI 10.1002/(SICI)1522-2594(200003)43:3<440::AID-MRM16>3.0.CO
[6]  
2-M
[7]   DYNAMIC POLARIZATION OF PROTONS, DEUTERONS, AND C-13 NUCLEI - THERMAL CONTACT BETWEEN NUCLEAR SPINS AND AN ELECTRON SPIN-SPIN INTERACTION RESERVOIR [J].
BOER, WD ;
BORGHINI, M ;
MORIMOTO, K ;
NIINIKOS.TO ;
UDO, F .
JOURNAL OF LOW TEMPERATURE PHYSICS, 1974, 15 (3-4) :249-267
[8]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[9]   Xenon-129 MR imaging and spectroscopy of rat brain using arterial delivery of hyperpolarized xenon in a lipid emulsion [J].
Duhamel, G ;
Choquet, P ;
Grillon, E ;
Lamalle, L ;
Leviel, JL ;
Ziegler, A ;
Constantinesco, A .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :208-212
[10]   13C-angiography [J].
Golman, K ;
Ardenkjær-Larsen, JH ;
Svensson, J ;
Axelsson, O ;
Hansson, G ;
Hansson, L ;
Jóhannesson, H ;
Leunbach, I ;
Månsson, S ;
Petersson, JS ;
Pettersson, G ;
Servin, R ;
Wistrand, LG .
ACADEMIC RADIOLOGY, 2002, 9 :S507-S510