High-contrast object localization and removal in cone-beam CT

被引:12
作者
Moseley, DJ [1 ]
Siewerdsen, JH [1 ]
Jaffray, DA [1 ]
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
来源
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2005年 / 5745卷
关键词
computed tomography; cone-beam CT; image-guided procedures; metal artifacts;
D O I
10.1117/12.595766
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In image-guided procedures high-contrast objects often appear in the imaging field-of-view for the purpose of guiding treatment (e.g., markers intended to localize the target) or delivering treatment (e.g., surgical tools, or in the case of brachytherapy, radioactive seeds). In cone-beam CT reconstructions, these high-contrast objects cause severe streak artifacts, CT number inaccuracy and loss of soft-tissue visibility. We have developed an iterative approach by which high-contrast objects are localized in the 2-D projection set by re-projecting conspicuities from the first-pass 3-D reconstruction. The projection operator, which finds the unique mapping from the world coordinate system to the detector coordinate system for each view angle, is computed from a geometric calibration of the system. In each projection, a two-dimensional 2(nd) order Taylor series is used to interpolate over the high-contrast objects. The interpolated surface is further modified using a local noise estimate to completely mask the objects. The algorithm has been applied to remove artifacts resulting from a small number of gold fiducial markers in patients being imaged daily with cone-beam CT for guidance of prostate radiotherapy. The algorithm has also been applied to post-operative images of a prostate brachytherapy patient in which the number of seeds can exceed similar to 100. In each case, the method provides excellent attenuation of image artifact and restoration of soft-tissue visibility. Using a local voxel based metric it was shown that the 2 d order Taylor series with added noise performed best at removing the high-contrast objects from the reconstruction volume.
引用
收藏
页码:40 / 50
页数:11
相关论文
共 19 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]   Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID [J].
Aubin, S ;
Beaulieu, L ;
Pouliot, S ;
Pouliot, J ;
Roy, R ;
Girouard, LM ;
Martel-Brisson, N ;
Vigneault, E ;
Laverdière, J .
MEDICAL PHYSICS, 2003, 30 (07) :1825-1832
[3]   A novel method for reducing high attenuation object artifacts in CT reconstructions [J].
Chen, LG ;
Liang, Y ;
Sandison, GA ;
Rydberg, J .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :841-850
[4]  
CHO Y, 2005, IN PRESS MED PHYS
[5]   Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities [J].
Fahrig, R ;
Holdsworth, DW .
MEDICAL PHYSICS, 2000, 27 (01) :30-38
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]   AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1981, 8 (06) :799-807
[8]   Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147
[9]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[10]   REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577