Biosensors for L-malate and L-lactate based on solid binding matrix

被引:48
作者
Katrlík, J
Pizzariello, A
Mastihuba, V
Svorc, J
Stred'ansky, M
Miertus, S
机构
[1] POLYtech SCRL, I-34012 Trieste, Italy
[2] Slovak Univ Technol Bratislava, Dept Dairy Technol, Bratislava 81237, Slovakia
[3] UNIDO, ICS, I-34012 Trieste, Italy
关键词
biosensor; L-malate; L-lactate; determination; wine; food analysis;
D O I
10.1016/S0003-2670(98)00610-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors for the selective determination of L-lactate and L-malate in wine based on robust solid composite transducers are presented. Transducers comprised a solid binding matrix having hydrophobic skeleton, e.g. 2-hexadecanone, graphite and NAD(+), The enzymes, L-malate or L-lactate dehydrogenase and diaphorase, were placed onto the transducer surface and covered by a dialysis membrane, which substantially reduced interferences derived from easily oxidable compounds, e.g. polyphenols, of wine. Hexacyanoferrate(III) was used as a mediator. The electrode responses were linear up to 1.1 mM for L-malate and 1.3 mM for L-lactate, The detection limit was at about 10 mu M. The biosensors showed an excellent long-term stability, after five months storage at room temperature, the L-malate sensor exhibited almost 100% and L-lactate 90% of the initial sensitivity, A multisensor composed of two enzyme electrodes allowing a simultaneous determination of L-malate and L-lactate was also constructed, The results obtained from the determination of both acids in wine samples by biosensors were in a good agreement with those obtained by liquid chromatography. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 23 条
[11]   UV-POLYMERIZABLE SCREEN-PRINTED ENZYME PASTES [J].
ROHM, I ;
KUNNECKE, W ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2304-2307
[12]   Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer [J].
Sampath, S ;
Lev, O .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2015-2021
[13]   The influence of the carbon paste composition on the performance of an amperometric bienzyme sensor for L-lactate [J].
Spohn, U ;
Narasaiah, D ;
Gorton, L .
ELECTROANALYSIS, 1996, 8 (06) :507-514
[14]   A bienzyme modified carbon paste electrode for the amperometric detection of L-lactate at low potentials [J].
Spohn, U ;
Narasaiah, D ;
Gorton, L ;
Pfeiffer, D .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :79-90
[15]   A REAGENTLESS, DISPOSABLE BIOSENSOR FOR LACTIC-ACID BASED ON A SCREEN-PRINTED CARBON ELECTRODE CONTAINING MELDOLAS-BLUE AND COATED WITH LACTATE DEHYDROGENASE, NAD+ AND CELLULOSE-ACETATE [J].
SPRULES, SD ;
HART, JP ;
WRING, SA ;
PITTSON, R .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :17-24
[16]   Composite transducers for amperometric biosensors. The glucose sensor [J].
Svorc, J ;
Miertus, S ;
Katrlik, J ;
Stredansky, M .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2086-2090
[17]  
SVORC J, 1995, Patent No. 02359
[18]   POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES [J].
WANG, J ;
VARUGHESE, K .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :318-320
[19]   FUMED-SILICA CONTAINING CARBON-PASTE DEHYDROGENASE BIOSENSORS [J].
WANG, J ;
LIU, J .
ANALYTICA CHIMICA ACTA, 1993, 284 (02) :385-391
[20]   LACTATE BIOSENSOR BASED ON A LACTATE-DEHYDROGENASE NICOTINAMIDE ADENINE-DINUCLEOTIDE BIOCOMPOSITE [J].
WANG, J ;
CHEN, Q .
ELECTROANALYSIS, 1994, 6 (10) :850-854