Long-term follow-up of metal-on-metal total hip replacement

被引:115
作者
Gruebl, Alexander
Marker, Martina
Brodner, Wolfram
Giurea, Alexander
Heinze, Georg
Meisinger, Vanee
Zehetgruber, Harald
Kotz, Rainer
机构
[1] Med Univ Vienna, Dept Orthopaed, A-1090 Vienna, Austria
[2] Med Univ Vienna, Core Unit Med Stat & Informat, A-1090 Vienna, Austria
[3] Med Univ Vienna, Clin Dept Occupat Med, Dept Internal Med 4, A-1090 Vienna, Austria
[4] Gen Hosp Krems, Dept Orthopaed, A-3500 Krems An Der Donau, Austria
关键词
total hip replacement; long-term results; metal-on-metal bearings; serum ion levels; serum cobalt concentration;
D O I
10.1002/jor.20381
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal-on-metal articulations were reintroduced to reduce polyethylene particle-induced osteolysis. Elevated serum metal levels have been detected at short- and intermediate-term follow-up. There is little knowledge about long-term effects of increased ionic metal generation. Our study was undertaken to provide information about long-term survival, clinical outcome, radiographic appearance, and serum metal concentrations after a minimum 10 years follow-up with a metal-on-metal hip prosthesis: 105 cementless primary total hip prostheses with metal-on-metal articulating surfaces were implanted in 98 patients with a mean age of 56 years. Clinical data, radiographs, and blood samples were obtained at a follow-up visit 10 years after implantation. Serum cobalt and chromium levels were determined with use of atomic absorption spectrometry. General laboratory analyses included a full blood count and kidney function parameters. The Harris score was 92 points and the UCLA score 6 points after 10 years. Small osteolytic lesions and radiolucent lines were found in Gruen's zones 1, 7, 8, and 14. The probability of survival was 98.6%. The median serum cobalt concentration of the 22 patients with their hip replacement as the only source of cobalt was 0.75 mu g/L (range, 0.3-50.1 mu g/L). No patient was diagnosed with renal insufficiency during the study period. Five patients were diagnosed with a malignancy between surgery and the follow-up. We do not have evidence of an increased rate of primary malignancies nor could we detect renal failure in our study group. Serum metal levels did not differ from short- and intermediate term follow-up values. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:841 / 848
页数:8
相关论文
共 30 条
[11]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[12]   CONCENTRATION OF WEAR PRODUCTS IN HAIR, BLOOD, AND URINE AFTER TOTAL HIP REPLACEMENT [J].
COLEMAN, RF ;
HERRINGTON, J ;
SCALES, JT .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 1 (5852) :527-529
[13]  
Davies AP, 2005, J BONE JOINT SURG BR, V87B, P1439, DOI 10.1302/0301-620X.87B10
[14]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[15]   Metal ion levels after metal-on-metal proximal femoral replacements - A 30-year follow-up [J].
Dunstan, E ;
Sanghrajka, AP ;
Tilley, S ;
Unwin, P ;
Blunn, G ;
Cannon, SR ;
Briggs, TWR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05) :628-631
[16]  
Grübl A, 2002, J BONE JOINT SURG AM, V84A, P425
[18]   Metal release in patients who have has a primary total hip arthroplasty - A prospective, controlled, longitudinal study [J].
Jacobs, JJ ;
Skipor, AK ;
Patteson, LM ;
Hallab, NJ ;
Paprosky, WG ;
Black, J ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1447-1458
[19]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[20]   In vitro toxicity and mutagenicity of CoCrMo and Ti6Al wear particles [J].
Katzer, A ;
Hockertz, S ;
Buchhorn, GH ;
Loehr, JF .
TOXICOLOGY, 2003, 190 (03) :145-154