Capillary electrochromatography. Abnormally high efficiencies for neutral-anionic compounds under reversed-phase conditions

被引:28
作者
Moffatt, F [1 ]
Cooper, PA [1 ]
Jessop, KM [1 ]
机构
[1] Zeneca Agrochem, Jealotts Hill Res Stn, Bracknell RG42 6ET, Berks, England
关键词
D O I
10.1021/ac981117x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Unusually high efficiencies (up to 2.5 million plates m(-1)) during the capillary electrochromatographic analysis of partially ionized anionic-neutral compounds have been observed under reversed-phase conditions using a standard C-18 stationary phase. An explanation has been proposed in terms of nonequilibrium conditions caused by pulses of stronger or weaker solvent that arise from the sample. The increased efficiencies are observed when the migration time of the analyte is closely matched to the elution time of sample-induced discontinuities in the mobile phase. Repeatability and hence the feasibility to control the system have been demonstrated along with the effect that separation parameters such as mobile-phase organic solvent content, ionic strength, and separation voltage have on peak efficiencies, areas, heights, and asymmetry. Van Deemter plots show that the B term (axial molecular diffusion) is the only major contributor to peak dispersion. A reduced plate height of 0.1 was obtained. The implications of this phenomenon and its ability to cause concurrent electrophoretic effects during the analysis of charged species, thus leading to even greater efficiencies, are discussed.
引用
收藏
页码:1119 / 1124
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   PREFERENTIAL SOLVATION OF SOLUTE AS A SOURCE OF GHOST PEAKS IN LIQUID-CHROMATOGRAPHY [J].
BEREK, D ;
BLEHA, T ;
PEVNA, Z .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1976, 14 (12) :560-563
[3]  
Burgi D. S., 1997, HDB CAPILLARY ELECTR
[4]   Investigation of peak compression effects in packed column supercritical fluid chromatography using chemometrics [J].
Carlsson, D ;
Strode, JT ;
Gyllenhaal, O ;
Karlsson, A ;
Karlsson, L .
CHROMATOGRAPHIA, 1997, 44 (5-6) :289-294
[5]  
Dittmann MM, 1995, LC GC-MAG SEP SCI, V13, P800
[6]  
Euerby MR, 1997, J MICROCOLUMN SEP, V9, P373
[7]   STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .3. REGULATION OF SYSTEM PEAK GRADIENT RETENTION FOR OBTAINING ANALYTE PEAK COMPRESSION [J].
FORNSTEDT, T ;
WESTERLUND, D ;
SOKOLOWSKI, A .
JOURNAL OF CHROMATOGRAPHY, 1990, 506 :61-74
[8]   Simplification of capillary electrochromatography procedures [J].
Frame, LA ;
Robinson, ML ;
Lough, WJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) :243-249
[9]   DEVELOPMENT OF PACKED CAPILLARY COLUMN ELECTROCHROMATOGRAPHY MASS-SPECTROMETRY [J].
GORDON, DB ;
LORD, GA ;
JONES, DS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :544-548
[10]  
KENNDLER E, 1993, CAPILLARY ELECTROKIN