Leaf position error during conformal dynamic arc and intensity modulated arc treatments

被引:40
作者
Ramsey, CR [1 ]
Spencer, KM [1 ]
Alhakeem, R [1 ]
Oliver, AL [1 ]
机构
[1] Thompson Canc Survival Ctr, Dept Radiat Oncol, Knoxville, TN 37921 USA
关键词
conformal dynamic arc; intensity modulation; multileaf collimator;
D O I
10.1118/1.1333410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conformal dynamic are (CD-ARC) and intensity modulated are treatments (IMAT) are both treatment modalities where the multileaf collimator (MLC) can change leaf position dynamically during gantry rotation. These treatment techniques can be used to generate complex isodose distributions, similar to those used in fix-gantry intensity modulation. However, a beam-hold delay cannot be used during CD-ARC or IMAT treatments to reduce spatial error. Consequently, a certain amount of leaf position error will have to be accepted in order to make the treatment deliverable. Measurements of leaf position accuracy were taken with leaf velocities ranging from 0.3 to 3.0 cm/s. The average and maximum leaf position errors were measured, and a least-squares linear regression analysis was performed on the measured data to determine the MLC velocity error coefficient. The average position errors range from 0.03 to 0.21 cm, with the largest deviations occurring at the maximum achievable leaf velocity (3.0 cm/s). The measured MLC velocity error coefficient was 0.0674 s for a collimator rotation of 0 degrees and 0.0681 s for a collimator rotation of 90 degrees. The distribution in leaf position error between the 0 degrees and 90 degrees collimator rotations was within statistical uncertainty. A simple formula was developed based on these results for estimating the velocity-dependent dosimetric error. Using this technique, a dosimetric error index for plan evaluation can be calculated from the treatment time and the dynamic MLC leaf controller file. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 10 条
[1]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[2]  
Boyer AL, 1999, MODERN TECHNOLOGY OF RADIATION ONCOLOGY, P437
[3]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[4]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[5]   Testing of dynamic multileaf collimation [J].
Chui, CS ;
Spirou, S ;
LoSasso, T .
MEDICAL PHYSICS, 1996, 23 (05) :635-641
[6]  
Dirican B, 1996, Radiat Med, V14, P293
[7]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[8]   Quality assurance of serial tomotherapy for head and neck patient treatments [J].
Low, DA ;
Chao, KSC ;
Mutic, S ;
Gerber, RL ;
Perez, CA ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :681-692
[9]   A comparison of beam characteristics for gated and nongated clinical x-ray beams [J].
Ramsey, CR ;
Cordrey, IL ;
Oliver, AL .
MEDICAL PHYSICS, 1999, 26 (10) :2086-2091
[10]   Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation [J].
Spirou, SV ;
Chui, CS .
MEDICAL PHYSICS, 1996, 23 (01) :1-8