Microfluidic chip-capillary electrophoresis device for the determination of urinary metabolites and proteins

被引:15
作者
Wu Ruige [1 ]
Fung, Y. S. [2 ]
机构
[1] Singapore Inst Mfg Technol, Singapore 638075, Singapore
[2] Univ Hong Kong, Dept Chem, Hong Kong, Hong Kong, Peoples R China
关键词
3-ELECTRODE ELECTROCHEMICAL DETECTOR; CONTACTLESS CONDUCTIVITY DETECTION; INDUCED FLUORESCENCE DETECTION; MAJOR INORGANIC-IONS; MICROCHIP ELECTROPHORESIS; URIC-ACID; ASCORBIC-ACID; LIQUID-CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; RAPID SEPARATION;
D O I
10.4155/bio.15.26
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic chip-CE (MC-CE) devices have caught recent attention for diagnostic applications in urine. This is due to the successes reported in handling real urine samples by integrating microfluidic chips (MC) with analyte enrichment and sample cleanup to CE with high separation efficiency and sensitive analyte detection. Here, we review the determination of urinary metabolites and proteins by MC-CE devices within the past 7 years. The application scope for MC-CE integrated devices was found to exceed the use of either technique alone, showing comparable performance to laser-induced fluorescence detection using less sensitive UV detectors, offering the flexibility to handle difficult urine samples with on-chip dilution and online standard addition and delivering enhanced performance as compared with commercial microfluidic chip electrophoresis chips.
引用
收藏
页码:907 / 922
页数:16
相关论文
共 65 条
[51]   Different techniques for urinary protein analysis of normal and lung cancer patients [J].
Tantipaiboonwong, P ;
Sinchaikul, S ;
Sriyam, S ;
Phutrakul, S ;
Chen, ST .
PROTEOMICS, 2005, 5 (04) :1140-1149
[52]   Proteomic analysis of normal human urinary proteins isolated by acetone precipitation or ultracentrifugation [J].
Thongboonkerd, V ;
Mcleish, KR ;
Arthur, JM ;
Klein, JB .
KIDNEY INTERNATIONAL, 2002, 62 (04) :1461-1469
[53]   Urinary proteome profiling using microfluidic technology on a chip [J].
Thongboonkerd, Visith ;
Songtawee, Napat ;
Sritippayawan, Suchai .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (05) :2011-2018
[54]   A new fabrication process for a microchip electrophoresis device integrated with a three-electrode electrochemical detector [J].
Tsai, DM ;
Lin, KW ;
Zen, JM ;
Chen, HY ;
Hong, RH .
ELECTROPHORESIS, 2005, 26 (15) :3007-3012
[55]   Comparison of the sensitivity of 2 automated immunoassays with immunofixation electrophoresis for detecting urine Bence Jones proteins [J].
Viedma, JA ;
Garrigós, N ;
Morales, S .
CLINICAL CHEMISTRY, 2005, 51 (08) :1505-1507
[56]   Determination of major inorganic ions in blood serum and urine by capillary electrophoresis with contactless conductivity detection [J].
Wan, QJ ;
Kubán, P ;
Tanyanyiwa, J ;
Rainelli, A ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 2004, 525 (01) :11-16
[57]   Microfabricated electrophoresis chip for bioassay of renal markers [J].
Wang, J ;
Chatrathi, MP .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :525-529
[58]   Rapid Determination of Creatinine in Human Urine by Microchip Electrophoresis with LED Induced Fluorescence Detection [J].
Wang, Shuping ;
Li, Xinchun ;
Yang, Jianping ;
Yang, Xiujuan ;
Hou, Fenghua ;
Chen, Zuanguang .
CHROMATOGRAPHIA, 2012, 75 (21-22) :1287-1293
[59]   Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection [J].
Wu, CC ;
Wu, RG ;
Huang, JG ;
Lin, YC ;
Chang, HC .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :947-952
[60]   Assessment of adulteration of soybean proteins in dairy products by 2D microchip-CE device [J].
Wu, Ruige ;
Wang, Zhiping ;
Fung, Ying Sing ;
Seah, Daphne Yen Peng ;
Yeung, William Shu-Biu .
ELECTROPHORESIS, 2014, 35 (11) :1728-1734