Development of x-ray laminography under an x-ray microscopic condition

被引:21
作者
Hoshino, Masato [1 ]
Uesugi, Kentaro [1 ]
Takeuchi, Akihisa [1 ]
Suzuki, Yoshio [1 ]
Yagi, Naoto [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst JASRI SPring 8, Sayo, Hyogo 6795198, Japan
关键词
biomedical imaging; biomembranes; cellular biophysics; X-ray microscopy; zone plates; HIGH-SPATIAL-RESOLUTION; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; SPECIMENS; RADIATION;
D O I
10.1063/1.3609865
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3609865]
引用
收藏
页数:6
相关论文
共 28 条
[21]   Submicrometer-resolution three-dimensional imaging with hard x-ray imaging microtomography [J].
Takeuchi, A ;
Uesugi, K ;
Takano, H ;
Suzuki, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (12) :4246-4249
[22]   Zernike phase-contrast x-ray microscope with pseudo-Kohler illumination generated by sectored (polygon) condenser plate [J].
Takeuchi, Akihisa ;
Uesugi, Kentaro ;
Suzuki, Yoshio .
9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
[23]   X-ray tomography of a microhabitat of bacteria and other soil colloids with sub-100 nm resolution [J].
Thieme, J ;
Schneider, G ;
Knöchel, C .
MICRON, 2003, 34 (6-7) :339-344
[24]   Three-dimensional observation of nanoscopic precipitates in an aluminum alloy by microtomography with Fresnel zone plate optics [J].
Toda, H. ;
Uesugi, K. ;
Takeuchi, A. ;
Minami, K. ;
Kobayashi, M. ;
Kobayashi, T. .
APPLIED PHYSICS LETTERS, 2006, 89 (14)
[25]   Development of high spatial resolution X-ray CT system at BL47XU in SPring-8 [J].
Uesugi, K ;
Suzuki, Y ;
Yagi, N ;
Tsuchiyama, A ;
Nakano, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :853-856
[26]   Fast tomography using quasi-monochromatic undulator radiation [J].
Uesugi, Kentaro ;
Sera, Toshihiro ;
Yagi, Naoto .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :403-407
[27]   Computed tomography of cryogenic biological specimens based on X-ray microscopic images [J].
Weiss, D ;
Schneider, G ;
Niemann, B ;
Guttmann, P ;
Rudolph, D ;
Schmahl, G .
ULTRAMICROSCOPY, 2000, 84 (3-4) :185-197
[28]   Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating [J].
Yashiro, W. ;
Takeda, Y. ;
Takeuchi, A. ;
Suzuki, Y. ;
Momose, A. .
PHYSICAL REVIEW LETTERS, 2009, 103 (18)