Attenuation correction for small animal PET tomographs

被引:108
作者
Chow, PL
Rannou, FR
Chatziioannou, AF
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
[2] Univ Santiago Chile, Dept Ingn Informat, Santiago, Chile
关键词
D O I
10.1088/0031-9155/50/8/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-sized and one rat-sized) and two animal subjects (one mouse and one rat) were scanned in CTI Concorde Microsystem's microPET((R)) Focus(TM) for emission and transmission data and in ImTek's MicroCAT(TM) II for transmission data. PET emission image values were calibrated against a scintillation well counter. Results indicate that the scale factor method of attenuation correction places the average measured activity concentration about the expected value, without correcting for the cupping artefact from attenuation. Noise analysis in the phantom studies with the PET-based method shows that noise in the transmission data increases the noise in the corrected emission data. The CT-based method was accurate and delivered low-noise images suitable for both PET data correction and PET tracer localization.
引用
收藏
页码:1837 / 1850
页数:14
相关论文
共 17 条
[1]   Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images [J].
Chatziioannou, A ;
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :290-294
[2]  
Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
[3]  
CHOW PL, 2002, MOL IMAGING BIOL, V4, pS17
[4]  
CHOW PL, 2004, MOL IMAGING SAINT LO, V3, P259
[5]  
CHOW PL, 2002, IEEE NUCL SCI S C RE, V2, P1298
[6]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[7]   ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT [J].
DEKEMP, RA ;
NAHMIAS, C .
MEDICAL PHYSICS, 1994, 21 (06) :771-778
[8]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[9]  
Hubbell JH, 2001, TABLES XRAY MASS ATT
[10]   SINGLES TRANSMISSION IN VOLUME-IMAGING PET WITH A CS-137 SOURCE [J].
KARP, JS ;
MUEHLLEHNER, G ;
QU, H ;
YAN, XH .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :929-944