Contamination free continuous flow microfluidic polymerase chain reaction for quantitative and clinical applications

被引:94
作者
Dorfman, KD
Chabert, M
Codarbox, JH
Rousseau, G
de Cremoux, P
Viovy, JL
机构
[1] Inst Curie, Sect Rec, Lab Physicochim Curie, CNRS UMR 168, F-75248 Paris, France
[2] Inst Curie, Sect Rec, Pharmacol Unit, F-75248 Paris, France
关键词
D O I
10.1021/ac050031i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a method for performing polymerase chain reaction (PCR) using isolated droplets flowing in an immiscible fluorinated solvent system. Thanks to an optimized control of interfacial properties, we could achieve in this capillary-based system reproducible amplification factors, without any detectable contamination between neighboring droplets. The system is readily amenable to further miniaturization and automation and serves as the first step toward a clinically viable, high-throughput, quantitative continuous flow PCR apparatus.
引用
收藏
页码:3700 / 3704
页数:5
相关论文
共 33 条
  • [1] Miniaturised nucleic acid analysis
    Auroux, PA
    Koc, Y
    deMello, A
    Manz, A
    Day, PJR
    [J]. LAB ON A CHIP, 2004, 4 (06) : 534 - 546
  • [2] GEMHEP multicenter quality control study of PCR detection of GB virus C hepatitis G virus RNA in serum
    Bogard, M
    BuffetJanvresse, C
    Cantaloube, JF
    Biagini, P
    Duverlie, G
    Castelain, S
    Izopet, J
    Dubois, M
    Defer, C
    Lepot, I
    Coste, J
    Marcellin, P
    MartinotPeignoux, M
    Halfon, P
    Gerolami, V
    Franguel, L
    Pawlotsky, JM
    RoudotThoraval, F
    Dussaix, E
    Loiseau, P
    Ravera, N
    Lewin, P
    Lamoril, J
    Lerable, J
    Bouchardeau, F
    Laperche, S
    Mariotti, M
    Lefrere, JJ
    Nicot, T
    Denis, F
    Gassain, M
    Merel, P
    Trepo, C
    Thiers, V
    Brechot, C
    Ferec, C
    Mercier, B
    StollKeller, F
    Palmer, P
    Lebon, P
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) : 3298 - 3300
  • [3] Exponential DNA replication by laminar convection
    Braun, D
    Goddard, NL
    Libchaber, A
    [J]. PHYSICAL REVIEW LETTERS, 2003, 91 (15)
  • [4] Real-time PCR as a new tool for quantifying Leishmania infantum in liver in infected mice
    Bretagne, S
    Durand, R
    Olivi, M
    Garin, JF
    Sulahian, A
    Rivollet, D
    Vidaud, M
    Deniau, M
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) : 828 - 831
  • [5] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [6] CHABERT M, UNPUB
  • [7] Thermosiphon-based PCR reactor: Experiment and modeling
    Chen, ZY
    Qian, SZ
    Abrams, WR
    Malamud, D
    Bau, HH
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (13) : 3707 - 3715
  • [8] A closed cycle capillary polymerase chain reaction machine
    Chiou, J
    Matsudaira, P
    Sonin, A
    Ehrlich, D
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (09) : 2018 - 2021
  • [9] Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification
    Curcio, M
    Roeraade, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (01) : 1 - 7
  • [10] The drop volume method for interfacial tension determination: An error analysis
    Earnshaw, JC
    Johnson, EG
    Carroll, BJ
    Doyle, PJ
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 177 (01) : 150 - 155