Optimization of physical dose distributions with hadron beams: Comparing photon IMRT with IMPT

被引:23
作者
Oelfke, U
Bortfeld, T
机构
[1] DKFZ, Dept Med Phys, D-69120 Heidelberg, Germany
[2] Northeast Proton Therapy Ctr, MGH, Boston, MA USA
关键词
D O I
10.1177/153303460300200505
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity modulated radiotherapy with high enengy photons (IMRT) and with charged particles (IMPT) refer to the most advanced development in conformal radiation therapy. Their general aim is to increase local tumor control rates while keeping the radiation induced complications below desired thresholds. IMRT is currently widely introduced in clinical practice. However, the more complicated IMPT is still under development. Especially, spot-scanning techniques integrated in rotating gantries that can deliver proton or light ion-beams to a radiation target from any direction will be available in the near future. We describe the basic concepts of intensity modulated particle therapy (IMPT). Starting from the potential advantages of hadron therapy inverse treatment planning strategies are discussed for various dose delivery techniques of IMPT Of special interest are the techniques of distal edge tracking (DET) and 3D-scanning. After the introduction of these concepts a study of comparative inverse treatment planning is presented. The study aims to identify the potential advantages of achievable physical dose distributions with proton and carbon beams, if different dose delivery techniques are employed. Moreover, a comparison to standard photon IMRT is performed. The results of the study are summarized as: i) IMRT with photon beams is a strong competitor to intensity modulated radiotherapy with charged particles. The most obvious benefit observed for charged particles is the reduction of medium and low doses in organs at risk. ii) The 3D-scanning technique could not improve the dosimetric results achieved with DET, although 10-15 times more beam spots were employed for 3D-scanning than for DET However, concerns may arise about the application of DET, if positioning errors of the patient or organ movements have to be accounted for. iii) Replacing protons with carbon ions leads to further improvements of the physical dose distributions. However, the additional degree of improvement due to carbon ions is modest. The main clinical potential of heavy ion beams is probably related to their radiobiological properties.
引用
收藏
页码:401 / 412
页数:12
相关论文
共 39 条
[1]  
ALONSO JR, 2000, P 7 EUR PART ACC C E, P235
[2]  
Bortfeld T, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P1
[3]   Optimized planning using physical objectives and constraints [J].
Bortfeld, T .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :20-+
[4]   DECOMPOSITION OF PENCIL BEAM KERNELS FOR FAST DOSE CALCULATIONS IN 3-DIMENSIONAL TREATMENT PLANNING [J].
BORTFELD, T ;
SCHLEGEL, W ;
RHEIN, B .
MEDICAL PHYSICS, 1993, 20 (02) :311-318
[5]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[6]   Potential role of intensity modulated proton beams in prostate cancer radiotherapy [J].
Cella, L ;
Lomax, A ;
Miralbell, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01) :217-223
[7]   Testing of dynamic multileaf collimation [J].
Chui, CS ;
Spirou, S ;
LoSasso, T .
MEDICAL PHYSICS, 1996, 23 (05) :635-641
[8]  
CLEMENTS R, 1999, RADIOTHERAPY ONCO S1, V51, P34
[9]  
Deasy JO, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P406
[10]   Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator [J].
DeNeve, W ;
DeWagter, C ;
DeJaeger, K ;
Thienpont, M ;
Colle, C ;
Derycke, S ;
Schelfhout, J .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (03) :271-279