Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups

被引:14
作者
Gottliebsen, Martin [1 ]
Rahbek, Ole
Ottosen, Per F. [2 ]
Soballe, Kjeld
Stilling, Maiken
机构
[1] Aarhus Univ Hosp, Orthopaed Res Lab, Dept Orthopaed, DK-8000 Aarhus C, Denmark
[2] Esbjerg Cty Hosp, Dept Orthopaed, Esbjerg, Denmark
关键词
Hydroxyapatite; Hip arthroplasty; Polyethylene wear; THA; Polyethylene; TOTAL HIP-ARTHROPLASTY; BACKED ACETABULAR CUPS; FOLLOW-UP; OSTEOLYSIS; PROSTHESES; PARTICLES; MIGRATION; FAILURE; COMPONENTS; REVISION;
D O I
10.5301/HIP.2012.9075
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Hydroxyapatite (HA) coating of implant surfaces is believed to improve longevity of uncemented total hip arthroplasty (THA). However; it is speculated that HA particles may cause third body wear of the polyethylene (PE) liner with subsequent osteolysis and aseptic loosening of implants. We performed a retrospective comparison of two patient populations with cementless Mallory-Head acetabular components. The patients were identified in the Danish hip arthroplasty Registry (DHR); 77 patients had HA-coated cups and 73 patients had non-HA coated cups. Anteroposterior (AP) radiographs were analysed for PE wear, osteolysis was quantified and survival of the acetabular components was compared. The mean follow-up was 11 years. There were no cup revisions in the HA group and 7 cup revisions in the non-HA group (P<0.01). The reason for revision in all cases was aseptic loosening of both stem and cup. The amount of osteolysis was significantly increased around cups in the non-HA group. The two-dimensional linear PE wear-rate of 0.18 mm/year was higher (P<0.001) in the group with HA coated cups compared with 0.12 mm/year in the group with non-HA coated cups. The mean age was lower (P=0.001) in the HA group (57 years) compared with the non-HA group (63 years). After 11.1 years of follow-up non-HA coated cups had a higher revision rate. Increased PE wear with HA-coated cups did not have a negative influence on the revision rate, but may result in a need for revision surgery over time.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 33 条
[1]
BAUER TW, 1995, ORTHOPEDICS, V18, P885
[2]
Aseptic loosening of 2 rim-fix, hydroxyapatite-coated acetabular cups [J].
Benkö, TZ ;
Santiago-Martin, A ;
Ruddlesdin, C ;
Selzer, G .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :519-523
[3]
High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses - 65 hips in 56 young patients followed for 5-9 years [J].
Blacha, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :276-282
[4]
Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty [J].
Chambers, Bryan ;
St Clair, Selvon F. ;
Froimson, Mark I. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (04) :71-74
[5]
Eight-year results of hydroxyapatite-coated hip arthroplasty [J].
Chang, Je-Ken ;
Chen, Chung-Hwan ;
Huang, Kuan-Yu ;
Wang, Gwo-Jaw .
JOURNAL OF ARTHROPLASTY, 2006, 21 (04) :541-546
[6]
Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components [J].
Coathup, MJ ;
Blackburn, J ;
Goodship, AE ;
Cunningham, JL ;
Smith, T ;
Blunn, GW .
BIOMATERIALS, 2005, 26 (19) :4161-4169
[7]
Cooper R A, 1992, J Arthroplasty, V7, P285, DOI 10.1016/0883-5403(92)90050-Z
[8]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P303
[9]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P317
[10]
Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107