Strategy for Rapid Identification and Antibiotic Susceptibility Testing of Gram-Negative Bacteria Directly Recovered from Positive Blood Cultures Using the Bruker MALDI Biotyper and the BD Phoenix System

被引:53
作者
Wimmer, Jana L. [1 ]
Long, S. Wesley [1 ,2 ]
Cernoch, Patricia [1 ]
Land, Geoffrey A. [1 ]
Davis, James R. [1 ]
Musser, James M. [1 ,2 ]
Olsen, Randall J. [1 ,2 ]
机构
[1] Methodist Hosp, Dept Pathol & Genom Med, Houston, TX 77030 USA
[2] Methodist Hosp, Res Inst, Ctr Mol & Translat Human Infect Dis Res, Houston, TX 77030 USA
关键词
DESORPTION IONIZATION-TIME; FLIGHT MASS-SPECTROMETRY; DIRECT INOCULATION; CLINICAL IMPACT; BOTTLES; VITEK-2;
D O I
10.1128/JCM.00409-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Decreasing the time to species identification and antibiotic susceptibility determination of strains recovered from patients with bacteremia significantly decreases morbidity and mortality. Herein, we validated a method to identify Gram-negative bacteria directly from positive blood culture medium using the Bruker MALDI Biotyper and to rapidly perform susceptibility testing using the BD Phoenix.
引用
收藏
页码:2452 / 2454
页数:3
相关论文
共 16 条
[1]  
[Anonymous], CUMITECH 1C BLOOD CU
[2]   Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing [J].
Barenfanger, J ;
Drake, C ;
Kacich, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (05) :1415-1418
[3]   Identification and susceptibility testing of Enterobacteriaceae and Pseudomonas aeruginosa by direct inoculation from positive BACTEC blood culture bottles into Vitek 2 [J].
Bruins, MJ ;
Bloembergen, P ;
Ruijs, GJHM ;
Wolfhagen, MJHM .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :7-11
[4]   Comparison of the MALDI Biotyper System Using Sepsityper Specimen Processing to Routine Microbiological Methods for Identification of Bacteria from Positive Blood Culture Bottles [J].
Buchan, Blake W. ;
Riebe, Katherine M. ;
Ledeboer, Nathan A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (02) :346-352
[5]  
Chen JR, 2008, J MICROBIOL IMMUNOL, V41, P259
[6]  
Clinical and Laboratory Standards Institute (CLSI), 2008, DEV IN VITR SUSC TES
[7]   CLINICAL IMPACT OF RAPID IN-VITRO SUSCEPTIBILITY TESTING AND BACTERIAL IDENTIFICATION [J].
DOERN, GV ;
VAUTOUR, R ;
GAUDET, M ;
LEVY, B .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (07) :1757-1762
[8]   Use of the BD PHOENIX automated identification and susceptibility testing positive blood cultures in a microbiology system for direct of gram-negative rods from three-phase trial [J].
Funke, G ;
Funke-Kissling, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) :1466-1470
[9]   Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates [J].
Gherardi, Giovanni ;
Angeletti, Silvia ;
Panitti, Miriam ;
Pompilio, Arianna ;
Di Bonaventura, Giovanni ;
Crea, Francesca ;
Avola, Alessandra ;
Fico, Laura ;
Palazzo, Carlo ;
Sapia, Genoveffa Francesca ;
Visaggio, Daniela ;
Dicuonzo, Giordano .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 72 (01) :20-31
[10]   Rapid identification and antimicrobial susceptibility testing of Gram-positive cocci in blood cultures by direct inoculation into the BD Phoenix system [J].
Lupetti, A. ;
Barnini, S. ;
Castagna, B. ;
Nibbering, P. H. ;
Campa, M. .
CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (07) :986-991