Aliphatic polyurethane as a matrix for pH sensors: Effects of native sites and added proton carrier on electrical and potentiometric properties

被引:37
作者
Cosofret, VV
Erdosy, M
Raleigh, JS
Johnson, TA
Neuman, MR
Buck, RP
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT MED,CHAPEL HILL,NC 27599
[3] CASE WESTERN RESERVE UNIV,METROHLTH MED CTR,CLEVELAND,OH 44109
关键词
polyurethane; pH sensors; electrical properties; potentiometric properties;
D O I
10.1016/0039-9140(95)01724-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potentiometric and impedance characteristics of polymeric membranes, based on aliphatic polyurethane (Tecoflex) as a matrix, are described and interpreted by theory and experiments for H+ and alkali metal ion-sensitive sensors. Both dummy plasticized membranes and proton carrier-loaded membranes can show pH response. The pH response of dummy membranes is due to protonated natural negative sites in the polyurethane matrix. The electrodes with added proton carrier show improved rejection of Li+, Na+, and K+ responses and give useful analytical responses. Optimal performance requires control of negative site concentration by addition of lipophilic salt (e.g. tetraphenylborate derivatives). Impedance analyses show surface-rate semicircles and, depending on the bathing electrolyte solution, appearance of a diffusional Warburg impedance. In addition to these time-dependence surface region effects, changes in the bulk membrane resistance with soaking time can be well correlated with equilibrium water content of plasticized membranes.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 44 条
  • [21] PLASTICIZED POLYVINYL-CHLORIDE) PROPERTIES AND CHARACTERISTICS OF VALINOMYCIN ELECTRODES .1. HIGH-FREQUENCY RESISTANCES AND DIELECTRIC-PROPERTIES
    HORVAI, G
    GRAF, E
    TOTH, K
    PUNGOR, E
    BUCK, RP
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (13) : 2735 - 2740
  • [22] Janata J., 1989, PRINCIPLES CHEM SENS
  • [23] LI Z, 1993, ANAL METHOD INSTRUM, V1, P30
  • [24] FLEXIBLE (KAPTON-BASED) MICROSENSOR ARRAYS OF HIGH-STABILITY FOR CARDIOVASCULAR APPLICATIONS
    LINDNER, E
    COSOFRET, VV
    UFER, S
    BUCK, RP
    KUSY, RP
    ASH, RB
    NAGLE, HT
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02): : 361 - 367
  • [25] ION-SELECTIVE MEMBRANES WITH LOW PLASTICIZER CONTENT - ELECTROANALYTICAL CHARACTERIZATION AND BIOCOMPATIBILITY STUDIES
    LINDNER, E
    COSOFRET, VV
    UFER, S
    BUCK, RP
    KAO, WJ
    NEUMAN, MR
    ANDERSON, JM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05): : 591 - 601
  • [26] RESPONSES OF H+ SELECTIVE SOLVENT POLYMERIC MEMBRANE ELECTRODES FABRICATED FROM MODIFIED PVC MEMBRANES
    LINDNER, E
    COSOFRET, VV
    KUSY, RP
    BUCK, RP
    ROSATZIN, T
    SCHALLER, U
    SIMON, W
    JENEY, J
    TOTH, K
    PUNGOR, E
    [J]. TALANTA, 1993, 40 (07) : 957 - 967
  • [27] RESPONSES OF SITE-CONTROLLED, PLASTICIZED MEMBRANE ELECTRODES
    LINDNER, E
    GRAF, E
    NIEGREISZ, Z
    TOTH, K
    PUNGOR, E
    BUCK, RP
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (04) : 295 - 301
  • [28] LIU CC, 1992, SELECT ELECTR REV, V14, P147
  • [29] POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES
    LIU, D
    MEYERHOFF, ME
    GOLDBERG, HD
    BROWN, RB
    [J]. ANALYTICA CHIMICA ACTA, 1993, 274 (01) : 37 - 46
  • [30] RESPONSE PROPERTIES OF ION-SELECTIVE POLYMERIC MEMBRANE ELECTRODES PREPARED WITH AMINATED AND CARBOXYLATED POLYVINYL-CHLORIDE)
    MA, SC
    CHANIOTAKIS, NA
    MEYERHOFF, ME
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2293 - 2299