Advanced scanning methods with tracking optical coherence tomography

被引:44
作者
Hammer, DX [1 ]
Ferguson, RD
Iftimia, NV
Ustun, T
Wollstein, G
Ishikawa, H
Gabriele, ML
Dilworth, WD
Kagemann, L
Schuman, JS
机构
[1] Phys Sci Inc, New England Business Ctr 20, Andover, MA 01810 USA
[2] Univ Pittsburgh, Sch Med, UPMC Eye Ctr,Dept Ophthalmol, Eye & Ear Inst,Ophthalmol & Visual Sci Res Ctr, Pittsburgh, PA 15213 USA
关键词
D O I
10.1364/OPEX.13.007937
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An upgraded optical coherence tomography system with integrated retinal tracker (TOCT) was developed. The upgraded system uses improved components to extend the tracking bandwidth, fully integrates the tracking hardware into the optical head of the clinical OCT system, and operates from a single software platform. The system was able to achieve transverse scan registration with sub-pixel accuracy (similar to 10 mu m). We demonstrate several advanced scan sequences with the TOCT, including composite scans averaged (co-added) from multiple B-scans taken consecutively and several hours apart, en face images collected by summing the A-scans of circular, line, and raster scans, and three-dimensional (3D) retinal maps of the fovea and optic disc. The new system achieves highly accurate OCT scan registration yielding composite images with significantly improved spatial resolution, increased signal-to-noise ratio, and reduced speckle while maintaining well-defined boundaries and sharp fine structure compared to single scans. Precise re-registration of multiple scans over separate imaging sessions demonstrates TOCT utility for longitudinal studies. En face images and 3D data cubes generated from these data reveal high fidelity image registration with tracking, despite scan durations of more than one minute. (c) 2005 Optical Society of America.
引用
收藏
页码:7937 / 7947
页数:11
相关论文
共 12 条
[1]   Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography [J].
Cense, B ;
Nassif, NA ;
Chen, T ;
Pierce, M ;
Yun, SH ;
Park, BH ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (11) :2435-2447
[2]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[3]   Wide-field retinal hemodynamic imaging with the tracking scanning laser ophthalmoscope [J].
Ferguson, RD ;
Hammer, DX ;
Elsner, AE ;
Webb, RH ;
Burns, SA .
OPTICS EXPRESS, 2004, 12 (21) :5198-5208
[4]   Tracking optical coherence tomography [J].
Ferguson, RD ;
Hammer, DX ;
Paunescu, LA ;
Beaton, S ;
Schuman, JS .
OPTICS LETTERS, 2004, 29 (18) :2139-2141
[5]  
FERGUSON RD, Patent No. 5943115
[6]  
FERGUSON RD, Patent No. 5767941
[7]   Active retinal tracker for clinical optical coherence tomography systems [J].
Hammer, DX ;
Ferguson, RD ;
Magill, JC ;
Paunescu, LA ;
Beaton, S ;
Ishikawa, H ;
Wollstein, G ;
Schuman, JS .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (02)
[8]   Compact scanning laser ophthalmoscope with high-speed retinal tracker [J].
Hammer, DX ;
Ferguson, RD ;
Magill, JC ;
White, MA ;
Elsner, AE ;
Webb, RH .
APPLIED OPTICS, 2003, 42 (22) :4621-4632
[9]   Image stabilization for scanning laser ophthalmoscopy [J].
Hammer, DX ;
Ferguson, RD ;
Magill, JC ;
White, MA ;
Elsner, AE ;
Webb, RH .
OPTICS EXPRESS, 2002, 10 (26) :1542-1549
[10]   In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve [J].
Nassif, NA ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Yun, SH ;
Bouma, BE ;
Tearney, GJ ;
Chen, TC ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (03) :367-376