An electrochemical detection of metallothioneins at the zeptomole level in nanolitre volumes

被引:75
作者
Adam, Vojtech [1 ,2 ]
Baloun, Jiri [1 ]
Fabrik, Ivo [1 ,3 ]
Trnkova, Libuse [4 ]
Kizek, Rene [1 ]
机构
[1] Mendel Univ Brno, Dept Chem & Biochem, CZ-61300 Brno, Czech Republic
[2] Mendel Univ Brno, Dept Anim Nutr & Forage Prod, Fac Agron, CZ-61300 Brno, Czech Republic
[3] Masaryk Univ, Dept Biochem, CZ-61137 Brno, Czech Republic
[4] Masaryk Univ, Dept Chem, Fac Sci, CZ-61137 Brno, Czech Republic
来源
SENSORS | 2008年 / 8卷 / 04期
关键词
proteomics; metallothionein; thiols; differential pulse voltammetry; Brdicka reaction; adsorptive transfer stripping technique; human blood serum; tumour disease; zeptomole;
D O I
10.3390/s8042293
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on improvement of the adsorptive transfer stripping technique ( AdTS) coupled with the differential pulse voltammetry Brdicka reaction to determine a thiol-protein. The current technique has been unable to generate reproducible results when analyzing very low sample volumes ( nanolitres). This obstacle can be overcome technically by modifying the current transfer technique including cooling step of the adsorbed analyte. We tested the technique on determination of a promising tumour disease marker protein called metallothionein ( MT). The detection limit ( 3 S/ N) of MT was evaluated as 500 zeptomoles per 500 nL ( 1 pM) and the quantification limit ( 10 S/ N) as 1,500 zeptomoles per 500 nL ( 3 pM). Further, the improved AdTS technique was utilized to analyze blood serum samples from patients with breast cancer. Based on the results obtained it can be concluded that the improved technique can be used to detect a thiol-protein in very low sample volumes and can also prevent interferences during the washing and transferring step.
引用
收藏
页码:2293 / 2305
页数:13
相关论文
共 59 条
[51]   Bio-inorganic speciation analysis by hyphenated techniques [J].
Szpunar, J .
ANALYST, 2000, 125 (05) :963-988
[52]   Trace element speciation analysis of biomaterials by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection [J].
Szpunar, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (2-3) :127-137
[53]   Advances in analytical methodology for bioinorganic speciation analysis: metallomics, metalloproteomics and heteroatom-tagged proteomics and metabolomics [J].
Szpunar, J .
ANALYST, 2005, 130 (04) :442-465
[54]   Elimination voltammetry with linear scan as a new detection method for DNA sensors [J].
Trnkova, L ;
Jelen, F ;
Petrlova, J ;
Adam, V ;
Potesil, D ;
Kizek, R .
SENSORS, 2005, 5 (6-10) :448-464
[55]   Electrochemical study of S-nitrosoglutathione and nitric oxide by carbon fibre NO sensor and cyclic voltammetry -: possible way of monitoring of nitric oxide [J].
Vitecek, Jan ;
Petrlova, Jitka ;
Petrek, Jiri ;
Adam, Vojtech ;
Potesil, David ;
Havel, Ladislav ;
Mikelova, Radka ;
Trnkova, Libuse ;
Kizek, Rene .
ELECTROCHIMICA ACTA, 2006, 51 (24) :5087-5094
[56]   Use of surface-modified capillaries in the separation and characterization of metallothionein isoforms by capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Wang, ZX ;
Prange, A .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :626-631
[57]   CZE-ICP-MS separation of metallothioneins in human brain cytosols:: comparability of electropherograms obtained from different sample matrices [J].
Wolf, C ;
Schaumlöffel, D ;
Richarz, AN ;
Prange, A ;
Brätter, P .
ANALYST, 2003, 128 (06) :576-580
[58]   An investigation of glutathione-platinum(II) interactions by means of the flow injection analysis using glassy carbon electrode [J].
Zitka, Ondrej ;
Huska, Dalibor ;
Krizkova, Sona ;
Adam, Vojtech ;
Chavis, Grace J. ;
Trnkova, Libuse ;
Horna, Ales ;
Hubalek, Jaromir ;
Kizek, Rene .
SENSORS, 2007, 7 (07) :1256-1270
[59]  
Zitka O, 2007, ACTA CHIM SLOV, V54, P68